Pre
Ǧ
Delivery/Annual
Inspection
Checklist
WARNING
AERIAL
PLATFORMS
SHALL
BE
INSPECTED,
SERVICED
AND
ADJUSTED
TO
MANUFACTURER'S
REQUIREMENTS
BY
A
QUALIFIED
MECHANIC
PRIOR
TO
EACH
SALE,
LEASE,
OR
RENTAL,
AND
EVERY
12
MONTHS
.
MODEL
NUMBER:
HB
Ǧ
P830
SERIAL
NUMBER
______________
x
Check
each
item
listed
below.
x
Use
proper
operating,
service,
and
maintenance
manual
for
specific
information
and
settings
x
If
an
item
is
found
to
be
unacceptable
make
the
necessary
repairs
and
check
the
“repaired”
box.
x
When
all
items
are
“acceptable”,
the
unit
is
ready
for
service.
Check
Y
N
R
Check
Y
N
R
Base:
Inspect
slide
tracks
for
damage
Decals:
All
frame
bolts
tight
Legibility
Pump
Secure
Correct
capacity
noted
DC
motor
secure
Proper
placement
quantity
Battery
Hold
Downs
Secure
Wiring:
Batteries
Fully
Charged
Switches
secure
Counterweights
secured
Contactor(s)
secure
Wheels:
Grease
Casters
Tight
on
terminals (No
loose
wiring)
Wheels:
Bolts/Nuts
Tight
Functions:
Maintenance
Locks:
Pins
in
storage
location
Elevate/Lower
Operational
All
Shields/Guards
in
place
Emergency
Stop
Breaks
Circuits
Hydraulic
Oil
Level
1”
from
top
Emergency
Down
Operational
Check
all
hydraulic
hoses
for
leaks
Battery
Charger
Secure/Operational
Check
all
hydraulic
fittings
for
leaks
Brakes:
Operational
Scissors:
Bubble
Level
in
Place
Broken
Welds
Bent
Beam
Members
All
rollers
Turn
Freely
Ret.
Rings
Secure
On
Pivots
Broken
welds
Platform:
All
rails
in
place/secure
No
bent
rails
No
broken
welds
Platform
power
outlet
safe/working
(if
installed)
Entrance
gate
Closes
Freely
Operator/Service
Manual
Included
Cables
in
place/secure
Comments:
̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴̴
Part #SUPO-615
REV H
Page 12 of 30
Part #SUPO-615
REV H
Page 13 of 30