1. INSTALLATION AND USE
3
1-
DPT100-S
1.2 CONFIGURATION
The printer set up print out (see fig. 1.4) includes a range of information, and
among these should be pointed out.
The printer’s configurable
(1)
parameters are:
•
Baud Rate: 38400, 19200, 9600
D
, 4800, 2400, 1200, 600.
•
Data length: 7, 8
D
bits/car.
•
Parity: None
D
, even or odd.
•
Handshaking: XON/XOFF
D
or Hardware.
•
Autofeed: CR deactivated
D
or CR activated.
•
Consumption: Low power, High power
D (2)
.
•
Print density: -2, -1, 0
D
, +1, +2.
Please note: the parameters marked with the symbol
D
represent the default
values.
(1)
Note: the printer interface is fixed setted to RS232.
(2)
Note: this parameter regulates the type of power supply setting; the default value
is High power. For further details please refers to the 1.2.1 section.
(Fig.1.4)
* SETUP DEFAULT *
HEAD TEMP. [
°
C] = 22.5
BATT TEMP. [
°
C] = 25.0
HEAD VOLT [V] = 6.3
Interface
:RS232
Baud Rate
: 9600 bps
Data length
: 8 bits/chr
Parity
: None
Handshaking
: Xon/Xoff
Autofeed
: CR disabled
Consumption
: High power
Print Density
: 0
[PUSH] ENTER SET-UP
[FAST PUSH] EXIT SET-UP