background image

11

010011

HEX

#8-32

2

NUT

41

011941

SPLIT LOCK

#8

2

WASHER

453

100453

TERMINAL

2

6

FIGURE I

Attach the boom to your mast as shown in Figure I.  First attach the
mounting plate (130) to the BA section of the boom using U-bolts
(404), washers (119), nuts (118), and V-blocks (63).  Attach the
mounting plate to the mast using the U-bolts (404), V-block (63),
washers(119) and nuts (118).  Return to the tuning section on page
1 for final checkout and tuning procedure.

KEY        P/N                     DISPLAY                         DESC                         SIZE                  QTY

63

170063

V-BLOCK

2"

4

(fits 404 U-Bolt) 

(5.1 cm)

118

010118

HEX

5/16"

8

NUT

(.8 cm)

119

010119

LOCK

5/16"

8

WASHER

(.8 cm)

404

010404

U-BOLT

2-1/8 x 3"

4

(5.4 x 7.6 cm)

130

190130

MOUNTING

3/16" x 6" x 6"

1

PLATE

  (.48 x 15.2 x 15.2 cm)

326

290326

DANGER

1

LABEL

#4 - RF CHOKE

A feedline should be prepared as shown in Figure H using the
solder terminals (453) provided.  A 1:1 balun may be installed
at the feedpoint but it is not required.  We recommend using
an RF choke made from 8 turns of RG8U coaxial cable with 6
inch (15.2 cm) diameter. 

 Important- Do not use foam dielectric

coax for your RF Choke because when the coax is wound in
a coil the center conductor may migrate away from the center
and detune your choke.  Attach th RF choke to the driven
element using washers (41) and nuts (11) as shown in Figure
H.  Be sure to tape and seal the feedline against water at the
point where the center dielectric and braid separate.  Tape the
feedline, between the feedpoint and the RF choke to the boom.
Tape the RF choke to the mast.  If you plan to install the antenna
in a salty or corrosive environment, you may want to consider
coating all elements with a clear marine varnish or its equivalent
after it is assembled.

#5 - BOOM TO MAST ASSEMBLY

KEY        P/N                     DISPLAY                         DESC                         SIZE                  QTY

A4S

FIGURE H

BOOM

130

404

404

MAST

63

119

118

118

119

119

118

63

63

63

118

119

118 119

118

119

404

Electrical

Tape

Warning

Do not use foam

dielectic coax cable.

326

453

453

6"

(15.2 cm)

4"

(10.16 cm)

41

8 Turns

11

41

11

Electrical

Tape

Summary of Contents for A4S

Page 1: ...A4S 20 15 10 MeterBeam ASSEMBLY AND INSTALLATION INSTRUCTIONS 951279 8 98 C O R P O R A T I O N ...

Page 2: ...non corrosive hardware For details and safety standards consult the National Electrical Code You should also use a coaxial lightning arrester Cushcraft offers several different models such as LAC 1 LAC 2 and the LAC 4 series ASSEMBLY Assemble your antenna by following the directions and illustrations in steps 1 through 5 After the antenna is completely assembled verify dimensions and element spaci...

Page 3: ...4 2 5 x 61 0 cm slotted 2 one end EP Aluminum tubing 1 2 x 48 1 3 x 121 9 cm 2 1 BOOM ASSEMBLY A4S 2 FIGURE A KEY PART QTY TB 15 meter director trap 2 TC 15 meter driv refl trap 4 TD 10 meter driv trap 2 TE 10 meter director trap 2 11 010011 8 32 hex nut 6 27 050027 5 8 Black plastic cap 2 41 011941 8 Split lock washer 6 53 050053 1 2 Black plastic caps 6 63 170063 2 1 2 Machined aluminum V blocks...

Page 4: ...tor at its center which is joined to tubes EB with a worm clamp 411 and pinning screws 123 as shown in Figure C Set dimensions to the desired band using Chart 1 and Chart 2 Tighten all clamps 4 2 Element Assembly KEY P N DISPLAY DESC SIZE QTY TD TB TC TE D4 EG 410 EE EA 411 410 TE TB 409 53 A4 410 C4 EF B4 EG 410 EE 411 410 TE TB 409 53 A4 410 C4 EF B4 D1 TC C1 EP 409 53 EL EK 412 B1 411 410 412 E...

Page 5: ...he ground so that moisture will not build up in the traps 3 ELEMENT MOUNTING 5 118 010118 SS HEX 5 16 8 NUT 8 cm 119 010119 SS LOCK 5 16 8 WASHER 8 cm 156 190156 ALUMINUM 2 X 1 1 8 4 BRACKET 5 08 X 2 86 cm 405 010405 U BOLT 2 1 8 x 4 4 5 4 x 10 2cm 76 194 3 cm 94 240 0 cm TE TB TE TB TC TC 1 2 40 102 8 cm 1 2 1 2 TD TC TD TC 108 2 73m FIGURE D A4S 2 5 1 cm Important Drain holes in traps should all...

Page 6: ... is not required We recommend using an RF choke made from 8 turns of RG8U coaxial cable with 6 inch 15 2 cm diameter Important Do not use foam dielectric coax for your RF Choke because when the coax is wound in a coil the center conductor may migrate away from the center and detune your choke Attach th RF choke to the driven element using washers 41 and nuts 11 as shown in Figure H Be sure to tape...

Page 7: ...enna is returned at purchasers expense to Cushcraft or one of its authorized representatives This warrranty is in lieu of all other expressed warranties any implied warranty is limited in duration to one year Cushcraft Corporation shall not be liablefor any incidental or consequential damages which may result from a defect Some states do not allow limitations on how long an implied warranty lasts ...