![Cusam CS-200BV-1 User Manual Download Page 9](http://html1.mh-extra.com/html/cusam/cs-200bv-1/cs-200bv-1_user-manual_2700380009.webp)
www.cusamintercom.com
8
☆
The door station provides a quick order "**43" if the room number
encoding method conforms to the rules of table 3.Use order “**40” to
eliminate the comparative table of the module address and the room
number".
☆
The manipulating setting of the extension phone number: press **15
and come up with Y011 after completes steps 1, 2, 3 (Y stands for the
address, the 2
nd
and 3
rd
figure stand for the coding site, and the 4
th
figure is the room number).Entering three numerals if you want to
revise the address, and press the key "*" if you don’t want to. It’ll show
four numerals after
finishing the above
steps.Please
enter
four numerals to
revise
(namely
room
number),
press "*" if do not
revise
(namely
examination),
and
then it will demonstrate the next encoding address.
If the four figures have been in table (namely
repetition), and it’ll show the repetitious number
address. Then please enter 0000,that mean you
don't use this address.
☆
The module(see the picture in the right corner),
the address of module ranges from 0101 to 9904.