Cusam CS-200BV-1 User Manual Download Page 1

www.cusamintercom.com 

 

 

CODING    INTERCOM 

 

         

 

 

 

USER’S    MANUAL 

 

 

Summary of Contents for CS-200BV-1

Page 1: ...www cusamintercom com 0 CODING INTERCOM USER S MANUAL ...

Page 2: ...phone 4 Description of Door station 5 System features 6 Ⅱ Technical parameter 6 Ⅲ Code setting 7 9 Ⅳ Use method and problem dealing 10 14 Ⅴ System schematic and wiring diagram 15 17 Ⅵ Door station setting order 18 Ⅶ User s operational order 19 Ⅷ Wrong code form 19 Ⅸ Entrance guard setup instructions 20 21 Ⅹ Attentions 21 23 ...

Page 3: ... 2 Ⅰ System instruction Coding video and audio intercom system mainly consists of the door station the module indoor phones the power source and so on which is extremely suit for the high building Main Products Door station ...

Page 4: ...www cusamintercom com 3 Indoor phones ...

Page 5: ...n View Picture On Indoor phone 4 Call Alarm Alarm may choose Button Activate Alarm 5 Unlock Button Operate Electric Door Lock 6 Microphone Speak to Visitor 7 Talk Button Telephone conversation 8 Brightness Adjust brightness of Indoor phone 9 Contrast Adjustment Adjust contrast of Indoor phone 10 Receiver Listen to Visitor 11 Volume Adjustment Adjust Volume of Indoor phone ...

Page 6: ...on Description Function 1 Camera Lens Sends Picture To Monitor 2 Night Vision Light LED Light Illuminates Area In Darkness 3 Speaker Enables You To Speak To Visitor 4 Door Bell Button Pressing Gives Ding Dong Sound 5 Microphone Enables Visitor To Speak To You ...

Page 7: ...o indoor phones can be installed with audio indoor phones together which is very flexible and convenient Ⅱ Technical parameter Working voltage DC10 8V 16V The undistorted power of output The main channel 5mw min The reply channel 100mw min Frequency response 300 3400HZ 3db Environment temperature 40 to 70 Humidity 45 to 95 Working current of camera 500mA 20mA Camera 1 3 CCD Definition 380 TV Line ...

Page 8: ...dialing Set code 7 you can dial three and four number mixly Please press to exit programming The quick establishing of the extension phone number Recommendation The door station provides a quick order 41 if the room number encoding method conforms to the rule of table 1 Just do as follows press 00 XXXX manager password 41 then it will come to the programming rule as table one does The door station...

Page 9: ...g site and the 4th figure is the room number Entering three numerals if you want to revise the address and press the key if you don t want to It ll show four numerals after finishing the above steps Please enter four numerals to revise namely room number press if do not revise namely examination and then it will demonstrate the next encoding address If the four figures have been in table namely re...

Page 10: ...serted in the single 1 and 2 contact pin Coding site 06 the sixth floor the block of short circuits should be inserted in the single 2 and 4 contact pin Coding site 19 the nineteenth floor the block of short circuits should be inserted in the single 1 and 8 and decimal 1 contact pin The room number 01 04 should be inserted in R01 R02 R03 R04 accordingly for example If the room number you want is 1...

Page 11: ...will shut off automatically after hanging off the phone If the coding is 3 and 4 dialing mixly for example you can dial 101 or 0101 either 2 The gate will be shut off by the closing machine automatically after the visitor entering into the door 3 The system may maintain the work by the reserving power source when the power is off 4 The resident can press monitor if he wants to monitor the situatio...

Page 12: ...floors cann t code and ring When you come across this kind of problems please separate the majority of modules and debug one by one until finding out the failure 7 When the door station call indoor phones and it sends two di di sound that mean it cann t detect the indoor phone If it sends three di di di sound that mean the wire of the indoor phone is short circuits When the door station call all i...

Page 13: ...503 09 03 0903 13 03 1303 01 04 0104 05 04 0504 09 04 0904 13 04 1304 02 01 0201 06 01 0601 10 01 1001 14 01 1401 02 02 0202 06 02 0602 10 02 1002 14 02 1402 02 03 0203 06 03 0603 10 03 1003 14 03 1403 02 04 0204 06 04 0604 10 04 1004 14 04 1404 03 01 0301 07 01 0701 11 01 1101 15 01 1501 03 02 0302 07 02 0702 11 02 1102 15 02 1502 03 03 0303 07 03 0703 11 03 1103 15 03 1503 03 04 0304 07 04 0704 ...

Page 14: ...001 09 03 1801 13 03 2601 01 04 0202 05 04 1002 09 04 1802 13 04 2602 02 01 0301 06 01 1101 10 01 1901 14 01 2701 02 02 0302 06 02 1102 10 02 1902 14 02 2702 02 03 0401 06 03 1201 10 03 2001 14 03 2801 02 04 0402 06 04 1202 10 04 2002 14 04 2802 03 01 0501 07 01 1301 11 01 2101 15 01 2901 03 02 0502 07 02 1302 11 02 2102 15 02 2902 03 03 0601 07 03 1401 11 03 2201 15 03 3001 03 04 0602 07 04 1402 ...

Page 15: ...3 09 03 0503 13 03 0703 01 04 0104 05 04 0304 09 04 0504 13 04 0704 02 01 0105 06 01 0305 10 01 0505 14 01 0705 02 02 0106 06 02 0306 10 02 0506 14 02 0706 02 03 0107 06 03 0307 10 03 0507 14 03 0707 02 04 0108 06 04 0308 10 04 0508 14 04 0708 03 01 0201 07 01 0401 11 01 0601 03 02 0202 07 02 0402 11 02 0602 126 02 6306 03 03 0203 07 03 0403 11 03 0603 126 03 6307 03 04 0204 07 04 0404 11 04 0604 ...

Page 16: ...www cusamintercom com 15 Ⅴ System schematic and wiring diagram 1 System structure schematic drawing ...

Page 17: ...www cusamintercom com 16 2 System wiring diagram ...

Page 18: ...www cusamintercom com 17 ...

Page 19: ...er opening the door 001 255seconds the talking time after opening the door Tacitly approves No is 20 09 000X demonstration type at standby state 0 9 Tacitly approves No is 1 0 off 1 9 are demostrating 10 000X Controlling thecode tube to demonstrate or to slake when picking up phone 0 1 Tacitly approves No is 1 0 is to slake 1 is to demonstrate 11 0XXX revising the alarm time 000 255seconds 000 clo...

Page 20: ...word operates the lock 250 XXXX XXXX eight password Ⅷ Wrong code form Mistake code Significance Wrong code Significance E01 Overtime mistake E07 The extension phone or the main line open circuit E02 Order mistake E08 The extension phone or the main line short circuits E03 Password mistake E09 Scope mistake of module address when coding in onmipotent coding E04 Data in over scope E10 The repetition...

Page 21: ...ful remark this is an adding card Take another blank card on the above of black short circuit block for 1 second a bibi sound successful named it is a deleting card Third Put the short circuit block cover on 1 Switch on the power 2 adding user cards put an adding card on the above of black short circuit block for 1 second a bibi sound red and green light flash alternately put a user card on the ab...

Page 22: ...both in networking and non networking system It s good for non networking upgrading to networking system If the door station promotes to the networking system then just replace the control chip of the non networking door station The non networking system promoting to the networking system needn t to change the wiring of the original unit and the networking networking system is called floor control...

Page 23: ... area of which should be bigger than 0 5mm2 and the length have to be less than 15M otherwise should enlarge the area of wire the possible problems if the wiring does not conform to the request 1 If the section area of mian line or branch line is too slim it may cause the indoor phones don t work when it is picked up or hanged off can t unlock the gate or the low volume of indoor phones and things...

Page 24: ...e is less than 50M The section area should be bigger than 1 0mm2 when the length of electric wire is less than 80M The section area should be bigger than 1 5mm2 when the length of electric wire is more than 80M General speaking every 4 to 8 floors should add a power source for video at this time you can let up the section area of wire suitably There is no special request that the line of surveilla...