background image

www.cusamintercom.com

0

VIDEO

VIDEO

VIDEO

VIDEO

INTERCOM

INTERCOM

INTERCOM

INTERCOM

SYSTEM

SYSTEM

SYSTEM

SYSTEM

FOR

FOR

FOR

FOR

APARTMENT

APARTMENT

APARTMENT

APARTMENT

(NETWORK)

(NETWORK)

(NETWORK)

(NETWORK)

USER

USER

USER

USER

’’’

S

S

S

S

MAUAL

MAUAL

MAUAL

MAUAL

QUZHOU

QUZHOU

QUZHOU

QUZHOU

ZHUOCHENG

ZHUOCHENG

ZHUOCHENG

ZHUOCHENG

ELECTRONIC

ELECTRONIC

ELECTRONIC

ELECTRONIC

CO.,LTD

CO.,LTD

CO.,LTD

CO.,LTD

Summary of Contents for CS-12V

Page 1: ...INTERCOM INTERCOM SYSTEM SYSTEM SYSTEM FOR FOR FOR APARTMENT APARTMENT APARTMENT NETWORK NETWORK NETWORK USER USER USER S S S MAUAL MAUAL MAUAL QUZHOU QUZHOU QUZHOU ZHUOCHENG ZHUOCHENG ZHUOCHENG ELEC...

Page 2: ...initializating room number and extension phone address the 1st kind 9 7 Table3 3 comparative table of initializating room number and extension phone address the 2nd kind 10 8 Table3 4 comparative tab...

Page 3: ...www cusamintercom com 2...

Page 4: ...ndoor phones phones phones input door station and indoor phone number the corresponding indoor phone ring and user can talk with managing center Door Door Door station station station call call call m...

Page 5: ...System 3 System 3 System schematic schematic schematic and and and W W Wiring iring iring diagram diagram diagram 1 1 1 System System System structure structure structure schematic schematic schemati...

Page 6: ...g wiring diagram diagram diagram Wiring Wiring Wiring Instruction Instruction Instruction Managing center to Audio and Video Switcher Vi GV VG GGV Audio GT Audio GG Audio and Video Swithcher to Door s...

Page 7: ...you want to change press if you don t say only check it then it will show the next address that s need to be set If the three figures you input have existed in the table that s say repetiton then it...

Page 8: ...k Door Door Door Station Station Station number number number and and and the the the first first first address address address Door Door Door Station Station Station No No No 001 001 001 032 032 032...

Page 9: ...ame with door station number setting The address of Network Module can be 127 04 at most If you want to code 100 01 or above address please enter from 99 04 and add by press and code when it comes to...

Page 10: ...ension extension extension phone phone phone address the address the address the 1 1 1st st st kind kind kind Module address coding site Room No Module address codin g site Room No Module address codi...

Page 11: ...1201 Y10 3 2001 Y14 3 2801 Y02 4 0402 Y06 4 1202 Y10 4 2002 Y14 4 2802 Y03 1 0501 Y07 1 1301 Y11 1 2101 Y15 1 2901 Y03 2 0502 Y07 2 1302 Y11 2 2102 Y15 2 2902 Y03 3 0601 Y07 3 1401 Y11 3 2201 Y15 3 30...

Page 12: ...to be set If you input 0000 means you don t use this address Quick Quick Quick setting setting setting If the coding method of indoor phones corresponds with rule of table 3 2 Then door station provid...

Page 13: ...want is 19 the block of short circuit should be inserted in 1 2 16 place You can get other module address according this method Coding site 01 04 connect with JP1 F01 JP2 F02 JP3 F03 JP4 F04 The compa...

Page 14: ...001 255 seconds Tacitly approves is 120 05 000X Choosing ringing type 0 9 0 is Dingdong sound 1 9 are phone sound Tacitly approves is 0 06 0XXX Revising waiting time after ringing 001 255 seconds the...

Page 15: ...11 16 17 are the factory tacitly approves No 21 000X Network or not 0 Non network tacity approve 1 Network Order Order Order Order Order Order code code code Following Following Following code code co...

Page 16: ...ve only when the short circuit block is inserted don t do anything on Sw4 keep the contact pin open circuit The number is building number reduce one 3 Network Switcher the scope is 0 31 it is effectiv...

Page 17: ...r It will show A J in digit tube and correspond with figure 1 9 0 Managing center will change letter into figure All room number must be figure 15 Edit comparative table of room number Reference the c...

Page 18: ...Table2 2 Table2 2 Wrong Wrong Wrong code code code form form form of of of managing managing managing center center center Wrong Wrong Wrong code code code Significance Significance Significance Wrong...

Page 19: ...rm alarm alarm 1 1 1 each each each room room room uses uses uses one 2 one 2 one 2 two two two rooms rooms rooms use use use one one one 4 4 4 four four four rooms rooms rooms use use use one one one...

Page 20: ...r 42 42 42 XX XX XX XX XX XX Previse Previse Previse the the the second second second room room room comparative comparative comparative table table table 49 49 49 XX XX XX XX XX XX Previst Previst Pr...

Page 21: ...een Between Between Network Network Network Switcher Switcher Switcher 485bus 485bus 485bus Under Under Under 500m 500m 500m 0 3mm 0 3mm 0 3mm2 2 2 500 1000m 500 1000m 500 1000m 0 5mm 0 5mm 0 5mm2 2 2...

Page 22: ...cher and Audio Video Switcher should use UPS seperately 2 The balance point of managing center and door station is affected by the lenth of cable So you must re adjust the balance Potentiometers 3 Whe...

Reviews: