This system is weak power system,so don’t use the same cable with

strong power

when it come across strong power,make sure the distance

between them is over 30cm or add a severance between them.

4

)、

The wiring connection must be with the same color

Don’t cut off the

grounding shielding(iron) wire.If it must be cut off because of construction,then

please reconsider after finishing the construction

The iron wire at the bottom

of the floor must be grounded

5

)、

All the connector must solder with tin to make sure the contact is

good.And add a thermal unit to protect it.

6

)、

For the convenience of construction and aegis,the wiring of terminal

must connect with right number.

Wiring

Wiring

Wiring

Wiring

Attentions

Attentions

Attentions

Attentions

1

Door Station,Network Switcher and Audio & Video Switcher should use

UPS seperately.

2

The balance point of managing center and door station is affected by the

lenth of cable.So you must re-adjust the balance Potentiometers

3

When there are more than one Audio and Video Switcher parallel

connect with one door station,there are many series of cable bus to Network

Module.In this condition,each cable bus can’t use the same electric cable,or

else it will interfere with each other.

4

There can’t be too long branch in 485 data bus and video bus.This

branch can cause signal reflex and data line mistake or two video pictures.It

will be better to use series connection,that’s the branch connector is in the

wiring terminal of each equipment.

5

The type and cross-sectional area of the wire, see table5.1.Please don’t

use wire with small cross-sectional area to instead of those wires with

big.Because the wire with big cross-sectional will enlarge the electric capacity

and assure performance of the system

Summary of Contents for CS-12V

Page 1: ...INTERCOM INTERCOM SYSTEM SYSTEM SYSTEM FOR FOR FOR APARTMENT APARTMENT APARTMENT NETWORK NETWORK NETWORK USER USER USER S S S MAUAL MAUAL MAUAL QUZHOU QUZHOU QUZHOU ZHUOCHENG ZHUOCHENG ZHUOCHENG ELEC...

Page 2: ...initializating room number and extension phone address the 1st kind 9 7 Table3 3 comparative table of initializating room number and extension phone address the 2nd kind 10 8 Table3 4 comparative tab...

Page 3: ...www cusamintercom com 2...

Page 4: ...ndoor phones phones phones input door station and indoor phone number the corresponding indoor phone ring and user can talk with managing center Door Door Door station station station call call call m...

Page 5: ...System 3 System 3 System schematic schematic schematic and and and W W Wiring iring iring diagram diagram diagram 1 1 1 System System System structure structure structure schematic schematic schemati...

Page 6: ...g wiring diagram diagram diagram Wiring Wiring Wiring Instruction Instruction Instruction Managing center to Audio and Video Switcher Vi GV VG GGV Audio GT Audio GG Audio and Video Swithcher to Door s...

Page 7: ...you want to change press if you don t say only check it then it will show the next address that s need to be set If the three figures you input have existed in the table that s say repetiton then it...

Page 8: ...k Door Door Door Station Station Station number number number and and and the the the first first first address address address Door Door Door Station Station Station No No No 001 001 001 032 032 032...

Page 9: ...ame with door station number setting The address of Network Module can be 127 04 at most If you want to code 100 01 or above address please enter from 99 04 and add by press and code when it comes to...

Page 10: ...ension extension extension phone phone phone address the address the address the 1 1 1st st st kind kind kind Module address coding site Room No Module address codin g site Room No Module address codi...

Page 11: ...1201 Y10 3 2001 Y14 3 2801 Y02 4 0402 Y06 4 1202 Y10 4 2002 Y14 4 2802 Y03 1 0501 Y07 1 1301 Y11 1 2101 Y15 1 2901 Y03 2 0502 Y07 2 1302 Y11 2 2102 Y15 2 2902 Y03 3 0601 Y07 3 1401 Y11 3 2201 Y15 3 30...

Page 12: ...to be set If you input 0000 means you don t use this address Quick Quick Quick setting setting setting If the coding method of indoor phones corresponds with rule of table 3 2 Then door station provid...

Page 13: ...want is 19 the block of short circuit should be inserted in 1 2 16 place You can get other module address according this method Coding site 01 04 connect with JP1 F01 JP2 F02 JP3 F03 JP4 F04 The compa...

Page 14: ...001 255 seconds Tacitly approves is 120 05 000X Choosing ringing type 0 9 0 is Dingdong sound 1 9 are phone sound Tacitly approves is 0 06 0XXX Revising waiting time after ringing 001 255 seconds the...

Page 15: ...11 16 17 are the factory tacitly approves No 21 000X Network or not 0 Non network tacity approve 1 Network Order Order Order Order Order Order code code code Following Following Following code code co...

Page 16: ...ve only when the short circuit block is inserted don t do anything on Sw4 keep the contact pin open circuit The number is building number reduce one 3 Network Switcher the scope is 0 31 it is effectiv...

Page 17: ...r It will show A J in digit tube and correspond with figure 1 9 0 Managing center will change letter into figure All room number must be figure 15 Edit comparative table of room number Reference the c...

Page 18: ...Table2 2 Table2 2 Wrong Wrong Wrong code code code form form form of of of managing managing managing center center center Wrong Wrong Wrong code code code Significance Significance Significance Wrong...

Page 19: ...rm alarm alarm 1 1 1 each each each room room room uses uses uses one 2 one 2 one 2 two two two rooms rooms rooms use use use one one one 4 4 4 four four four rooms rooms rooms use use use one one one...

Page 20: ...r 42 42 42 XX XX XX XX XX XX Previse Previse Previse the the the second second second room room room comparative comparative comparative table table table 49 49 49 XX XX XX XX XX XX Previst Previst Pr...

Page 21: ...een Between Between Network Network Network Switcher Switcher Switcher 485bus 485bus 485bus Under Under Under 500m 500m 500m 0 3mm 0 3mm 0 3mm2 2 2 500 1000m 500 1000m 500 1000m 0 5mm 0 5mm 0 5mm2 2 2...

Page 22: ...cher and Audio Video Switcher should use UPS seperately 2 The balance point of managing center and door station is affected by the lenth of cable So you must re adjust the balance Potentiometers 3 Whe...

Reviews: