DuraCOR 310
Chapter 6 Specifications
MNL-0666-01 Rev A3
ECO-5479
Effective: 26 Apr 18
Page 43 of 51
EMI/EMC
To be Qualified to MIL-STD-461F and DO-160G:
Conducted Emissions
MIL-STD-461F CE102; Power Leads, 10 kHz to 10 MHz
Basic Curve, Figure CE102-1
DO-160G Sec. 21; Conducted RF Emissions, 150 kHz to 152 MHz
Category L; Figures 21-1, 21-2
Conducted Susceptibility
MIL-STD-461F CS101; Power Leads, 30 Hz to 150 kHz
Curve 2, Figure CS101-1 (28V and below)
DO-160G Sec. 20; Conducted Susceptibility, 10 kHz to 400 MHz
Category M; Figure 20-6
Radiated Emissions
MIL-STD-461F RE102; Electric Field, 10 kHz to 18 GHz
Fixed Wing Internal < 25 meters, Figure RE102-3
DO-160G Sec. 21; Radiated RF Emissions, 100 MHz to 6 GHz
Category L; Figure 21-7
Radiated Susceptibility
MIL-STD-461F RS103; Electric Field, 2 MHz to 18 GHz
200V/m, Table VII, RS103 limits
DO-160G Sec. 20; Radiated Susceptibility, 100 MHz to 8 GHz
Category R; Figure 20-10
Operating Conditions
Humidity: Up to 95% RH @ 65C, Non-Condensing (Conformal Coated)
Water Immersion: 1 Meter Submersion, 30 Minutes (Similar to IP67)
Dust Ingress: Designed for Compliance w/Method 510.4, No Dust Ingress
Operating Altitude: Up to 75,000ft (meters); Thermal De-rating May Apply
Storage Altitude: Sea Level to 75,000ft (meters)
Other Specifications
Reliability
No Moving Parts; Passive Cooling; Conformal Coated Boards for Humidity and Tin Whisker
Mitigation
Designed and manufactured using AS9100 Aerospace Grade/ISO 9001:2000 Certified Quality
Program
Assembled to IPC-A-610 Class III Workmanship
MTBF: See Qualification Test Report.