background image

28
29
30
31
32
33
36
37
38
39
40
41
42
43
44
45
46
47
48
50
51
52
53
54
55

  1
  2
  3
  4
  5
  6
  7
  8
  9
10
11
12
13
14
15
15A
16
17
18
19
20
21
22
23
26

WC-3322
WC-3320
WC-3201
WC-4003
WC-3992
WC-3963
WC-3647
WC-  655
WC-  202
WC-  114R
WC-  122
WC-39119
WC-4213
WC-2906
WC-54001
WC-54002
WC-4502
WC-5310
WC-2965
WC-1411
WC-  895
WC-2977
WC-4436
WC-  517
WC-2401

BREW BASKET, WIRE
BREW CONE/HANDLE ASSY
BREW CONE HANDLE
NUT, 10-32 RETAINER
LABEL, ICED TEA BREW CONE
STICKER, CAUTION BREW CONE
STRAINER
TIMER, DUAL 115V
BREW LIGHT, 115V
SWITCH, ON/OFF 115V
SWITCH, BREW 115V
LABEL, SWITCH PANEL
LOCK NUT, BRASS 5/8"
SPRAYHEAD, BLUE
COVER, FRONT, TCB-35S
COVER, FRONT, TCB-35
SCREW, 8-32 x 3/8" PAN HEAD
TUBING, SILICONE 5/16"
SPOUT, BYPASS
BUSHING, SNAP-IN 5/8"
VALVE, INLET DUAL 120V 10W
FITTING, SPRAYHEAD 45°
SCREW, 4x3/8 PHIL PAN HEAD
THERMOSTAT, CAPILLARY SPST
FITTING, 1/4 x 1/8 FLARE ELBOW

WC-54006
WC-1200
WC-1408
WC-  102
WC-54047
WC-3685
WC-5851
WC-43062
WC-29010
WC-4320
WC-6210
WC-4373
WC-2970
WC-  904-04
WC-5409
WC-29009
WC-4306
WC-4243
WC-4212
WC-4381
WC-  522
WC-54048
WC-3502
WC-4394
WC-4506

COVER, TOP BREWER*
POWER CORD, 125V, 6'
CORD GRIP, 7/8"
TOGGLE SWITCH, 125V, 20A
HEATING TANK W/FITTINGS
INSULATION, WRAP
LID, TANK
GASKET, TANK LID
FITTING OVERFLOW, BARBED
O' RING SEAL, 1/2"
SHIELD, BUBBLE
O' RING, 3/4"
FITTING, SIPHON TUBE
ELEMENT, HEATING 1.6KW 120V
CLIP, THERMOSTAT BULB
FITTING, TANK INLET/DRAIN
WASHER, .875 O.D X .562ID SILICONE
LOCK NUT, 3/4" BRASS
JAM NUT, 5/8" BRASS
SHOCK GUARD, RST T'STAT
THERMOSTAT, HI LIMIT HEATER DPST
HEATING TANK COMPLETE
RUBBER FEET, 8-32 STUD
SHOCK GUARD, HEAT ELEMENT
SCREW, 8-32 x 5/8 SS PAN HD

The part numbers mentioned in this section are for 120 volt components only. For 220 volt part
numbers, see the -30 wiring diagram.

PARTS LIST - TCT-35 & TCT-35S, ICED TEA BREWER

 PRE-'94 PRODUCTION HAD 16¾" LONG TOP COVER.

- 7 -

DESCRIPTION

PART

ITEM

DESCRIPTION

PART

ITEM

Summary of Contents for TCT-35

Page 1: ...vice manual is information on the TCT 35 and TCT 35S The information is common to both TCT brewers except where noted For 220 volt units a separate wiring diagram and parts list will be provided FOR T...

Page 2: ...ee water flowing switch off the ON RESET switch d The water level in the heating tank is now correct and the machine is ready to brew e Make sure the READY TO BREW light is on This indicates the water...

Page 3: ...at is packaged in a filter pack it is recommended that the water spreader portion of the two piece Sprayhead be removed This will allow for a single stream of hot water to pour directly onto the tea p...

Page 4: ...inals of each coil If there is no voltage replace the timer PROBLEM No hot water flowing from Sprayhead Only cold water cycles POSSIBLE CAUSE SOLUTION Faulty Water Inlet Valve Coil WC 824 Faulty Brew...

Page 5: ...oak for at least one minute 6 Thoroughly rinse parts with clear hot water 7 Air dry all parts that were sanitized 8 After cleaning sanitizing and drying assemble any partstaken from the TCT 35 and tea...

Page 6: ...5...

Page 7: ...TCT 35 TCT 35S 6 A 12 12 12 123 123 123 123 123 123 2 1 3 4 5 6...

Page 8: ...ITTING 1 4 x 1 8 FLARE ELBOW WC 54006 WC 1200 WC 1408 WC 102 WC 54047 WC 3685 WC 5851 WC 43062 WC 29010 WC 4320 WC 6210 WC 4373 WC 2970 WC 904 04 WC 5409 WC 29009 WC 4306 WC 4243 WC 4212 WC 4381 WC 52...

Page 9: ...8 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 10: ...g water flow rate 5 Adjustments and cleaning The resetting of safety thermostats and circuit breakers programming and temperature adjustments are the responsibility of the equipment owner The owner is...

Reviews: