background image

Curtis enGage™ IV Manual

page 6

mode = NORM

mode = MENU

Main Menu 1
10 CHANGE SETTINGS
20 MAINT. MONITORS
30 METRIC/ENGLISH
40 SET CLOCK
50 EXIT MENU

Sub-menu 10
11 ADVANCED SETTINGS
12 CHANGE PASSWORD
1x EXIT

Sub-menu 40
41 SELECT 12/24  12H
42 SET CLOCK  HH:MM
4x EXIT

        No Sub-menus

Sub-menu 30
31 METRIC/ENGLISH   X
3x EXIT

        No Sub-menus

Password Level 2

Sub-menu 11
11.1 SET MM INTERVALS
11.2 SET HOURMETERS
11.3 SET BDI PROFILE
11.4 RUN DIAGNOSTICS
11.x EXIT

Sub-menu 20
21 RESET ALL
22 RESET MAINT. MON. 1
23 RESET MAINT. MON. 2
24 RESET MAINT. MON. 3
2x EXIT

Sub-menu 12

12.1 ENTER NEW USER P/W:
12.2 ENTER NEW OEM P/W:
12.x EXIT

Password Level 1

NOTES: 1. ALL MENUS EXIT TO THEIR PARENT MENU

2. SOME ENTRIES NOT AVAILABLE IF FUNCTION
    IS NOT AVAILABLE
3. KEYSWITCH OFF/ON EXITS THE MENU

FUNCTIONALITY:
Press ENTER for 3 Sec
to enter MENU mode
Press UP/DN to navigate
ENTER to select
UP/DN to change
ENTER to accept

Sub-menu 111
11.11 SET MM 1 INTERVAL
11.12 SET MM 2 INTERVAL
11.13 SET MM 3 INTERVAL
11.1x EXIT

Sub-menu 112
11.21 RESET ALL
11.22 SET HRM 1
11.23 SET HRM 2
11.24 SET HRM 3
11.2x EXIT

Sub-menu 113
11.31 SET BDI CTR FULL
11.32 SET BDI CTR EMPTY
11.33 SET BDI OCR
11.34 SET BDI ...
11.3x EXIT

Sub-menu 114
11.41 ANALOG INPUTS
11.42 DIGITAL INPUTS
11.43 MOSFETS
11.44 LCD HEATER
11.4x EXIT

Sub-menu 1121
11.211 HRM 1  HHHHH.h
11.212 HRM 2  HHHHH.h
11.213 HRM 3  HHHHH.h
11.214 RESET
11.21x EXIT

Sub-menu 1122
11.221 HRM 1  HHHHH.h
11.22x EXIT

Sub-menu 1123
11.231 HRM 2  HHHHH.h
11.23x EXIT

Sub-menu 1124
11.241 HRM 3  HHHHH.h
11.24x EXIT

Sub-menu 21
21.1 MM 1

HHH

21.2 MM 2

HHH

21.3 MM 3

HHH

21.4 RESET
21.x EXIT

Sub-menu 22
22.1 MM 1

HHH

22.x EXIT

Sub-menu 23
23.1 MM 2

HHH

23.x EXIT

Sub-menu 24
24.1 MM 3

HHH

24.x EXIT

2.6.3 enGage™ IV Menu System Navigation

The diagram below illustrates the navigation through the menu system.

enGage IV Menu System

Summary of Contents for enGage IV

Page 1: ...M MA AN NU UA AL L DIGITAL INSTRUMENTATION...

Page 2: ...lly consumes 310mA when active The backlight circuit typically consumes 30mA For higher V voltages the operating current is reduced accordingly enGage IV Operating Current mA Without Backlight With Ba...

Page 3: ...s Only to 80 C Thermal Shock As per SAE J1455 section 4 1 3 2 Applicable To Enclosed Units Only to 80 C Humidity 95 RH non condensing at 38 C Applicable To Enclosed Units Only as per SAE J1455 section...

Page 4: ...requency 7 Switched Input 1 8 Switched Input 2 9 Switched Input 3 10 Switched Input 4 11 Switched Input 5 12 Switched Input 6 13 Keyswitch Input 14 MOSFET output 1 15 MOSFET output 2 16 MOSFET output...

Page 5: ...ounting Enclosed unit snaps into panel cutout using molded in fingers An optional mounting bracket Curtis P N 17644307 can be used for additionsal support Module units are attached via screw holes in...

Page 6: ...Following a power up sequence the OEM logo if applicable will be displayed Once the start up process is complete the specified default normal monitoring screen will appear 2 6 1 enGage IV Menu System...

Page 7: ...U mode Press UP DN to navigate ENTER to select UP DN to change ENTER to accept Sub menu 111 11 11 SET MM 1 INTERVAL 11 12 SET MM 2 INTERVAL 11 13 SET MM 3 INTERVAL 11 1x EXIT Sub menu 112 11 21 RESET...

Page 8: ...to the main menu by utilizing the up down arrows on panel and select Exit 2 6 4 3 Set Clock Starting from the main menu choose Set Clock then Set Clock again Once the left button is pressed to select...

Page 9: ...scribed earlier 3 1 Auto range BDI Curtis enGage IV has an operating voltage range for V from 12 to 80 VDC 25 The source to which pin J1 17 is connected will configure the instrument for the correct B...

Page 10: ...strument voltage range selected does not match battery voltage Range Select V connected to wrong terminal Will Not Reset Instrument voltage does not match battery voltage Battery not fully charged Bat...

Page 11: ...roper voltage Stays At Sender or Sender Connection Problems Maximum Minimum Sender connected to wrong terminal Incorrect sender used Maintenance Function Problem Possible Cause Will Not Reset Procedur...

Page 12: ...ions subject to change without notice 2004 CURTIS INSTRUMENTS INC 53040 REV A 2 04 CURTIS INSTRUMENTS INC 200 Kisco Avenue Mt Kisco New York 10549 USA Tel 914 666 2971 Fax 914 666 2188 www curtisinstr...

Reviews: