4.0 Trouble-shooting
General
Problem
Possible Cause
No Display
V+ (keyswitch) voltage not present at J1-13.
Battery voltage too low. Battery terminals
not connected.
BDI Function
Problem
Possible Cause
No Display
Terminals Not Connected.
Improper Voltage – Check Pin J1-17
Stays At FULL
Instrument voltage range selected does not
match battery voltage.
Range Select V+ connected to wrong
terminal.
Will Not Reset
Instrument voltage does not match battery
voltage.
Battery not fully charged.
Battery may be defective.
Resets Without
Not connected directly to battery terminals.
Charging Battery
Empty Too Soon
Range Select V+ connected to wrong
terminal.
Instrument voltage does not match battery
voltage.
Terminals not connected directly to battery.