DIGITAL INSTRUMENTATION

Summary of Contents for enGage IV

Page 1: ...M MA AN NU UA AL L DIGITAL INSTRUMENTATION...

Page 2: ...lly consumes 310mA when active The backlight circuit typically consumes 30mA For higher V voltages the operating current is reduced accordingly enGage IV Operating Current mA Without Backlight With Ba...

Page 3: ...s Only to 80 C Thermal Shock As per SAE J1455 section 4 1 3 2 Applicable To Enclosed Units Only to 80 C Humidity 95 RH non condensing at 38 C Applicable To Enclosed Units Only as per SAE J1455 section...

Page 4: ...requency 7 Switched Input 1 8 Switched Input 2 9 Switched Input 3 10 Switched Input 4 11 Switched Input 5 12 Switched Input 6 13 Keyswitch Input 14 MOSFET output 1 15 MOSFET output 2 16 MOSFET output...

Page 5: ...ounting Enclosed unit snaps into panel cutout using molded in fingers An optional mounting bracket Curtis P N 17644307 can be used for additionsal support Module units are attached via screw holes in...

Page 6: ...Following a power up sequence the OEM logo if applicable will be displayed Once the start up process is complete the specified default normal monitoring screen will appear 2 6 1 enGage IV Menu System...

Page 7: ...U mode Press UP DN to navigate ENTER to select UP DN to change ENTER to accept Sub menu 111 11 11 SET MM 1 INTERVAL 11 12 SET MM 2 INTERVAL 11 13 SET MM 3 INTERVAL 11 1x EXIT Sub menu 112 11 21 RESET...

Page 8: ...to the main menu by utilizing the up down arrows on panel and select Exit 2 6 4 3 Set Clock Starting from the main menu choose Set Clock then Set Clock again Once the left button is pressed to select...

Page 9: ...scribed earlier 3 1 Auto range BDI Curtis enGage IV has an operating voltage range for V from 12 to 80 VDC 25 The source to which pin J1 17 is connected will configure the instrument for the correct B...

Page 10: ...strument voltage range selected does not match battery voltage Range Select V connected to wrong terminal Will Not Reset Instrument voltage does not match battery voltage Battery not fully charged Bat...

Page 11: ...roper voltage Stays At Sender or Sender Connection Problems Maximum Minimum Sender connected to wrong terminal Incorrect sender used Maintenance Function Problem Possible Cause Will Not Reset Procedur...

Page 12: ...ions subject to change without notice 2004 CURTIS INSTRUMENTS INC 53040 REV A 2 04 CURTIS INSTRUMENTS INC 200 Kisco Avenue Mt Kisco New York 10549 USA Tel 914 666 2971 Fax 914 666 2188 www curtisinstr...