![Curtis CT Series Instruction Manual Download Page 30](http://html.mh-extra.com/html/curtis/ct-series/ct-series_instruction-manual_2700238030.webp)
CT SERIES
CAP 410
WIRING PROCEDURE
FOR
3 PHASE FIELD MOUNTED MOTOR STARTER
CONNECT INCOMING
POWER WIRES TO
STARTER TERMINALS
L1, L2, L3
CONNECT ONE WIRE
FROM PRESSURE SWITCH
TO STARTER TERMINAL
L1.
CONNECT SECOND
WIRE FROM PRESSURE
SWITCH TO STARTER
COIL TERMINAL A2.
CONNNECT MOTOR
LEADS TO T1, T2, T3.
THERMAL
OVERLOADS (3)
TURN OFF POWER BEFORE SERVICING!!!
1. CONNECT MOTOR LEADS AS PER DIAGRAM ON MOTOR NAMEPLATE
TO STARTER TERMINALS T1, T2 & T3 CONNECT ONE WIRE FROM
PRESSURE SWITCH TO STARTER TERMINAL L1 (USE 18 GAUGE
WIRE).
2. CONNECT 2
ND
WIRE FROM PRESSURE SWITCH TO STARTER COIL
TERMINAL A2 (USE 18 GAUGE WIRE). A2 IS OPEN SPADE CLIP
BEHIND L3.
3. CONNECT INCOMING POWER LINES TO STARTER TERMINALS
L1, L2 & L3.
4. COMPRESSOR FLYWHEEL ROTATION SHOULD BE
COUNTERCLOCKWISE WHEN FACING FLYWHEEL.
5. IF COMPRESSOR FLYWHEEL ROTATION IS REVERSED,
INTERCHANGE INCOMING POWER WIRES TO STARTER TERMINALS
L1 & L2.
PAGE 28
Summary of Contents for CT Series
Page 8: ...CT SERIES CAP 410 EXPLODED VIEW VERTICAL 5HP 60 GALLON MODEL 555VT6 PAGE 6 ...
Page 10: ...CT SERIES CAP 410 PAGE 8 EXPLODED VIEW VERTICAL 5HP 80 GALLON MODEL 555VT8 ...
Page 12: ...CT SERIES CAP 410 PAGE 10 EXPLODED VIEW VERTICAL 7 1 2HP 80 GALLON MODEL 755VT8 ...
Page 14: ...CT SERIES CAP 410 PAGE 12 EXPLODED VIEW VERTICAL 7 1 2HP 80 GALLON MODEL 775VT8 ...
Page 16: ...CT SERIES CAP 410 PAGE 14 EXPLODED VIEW VERTICAL 10HP 80 GALLON MODEL 1075VT8 ...
Page 18: ...CT SERIES CAP 410 PAGE 16 EXPLODED VIEW HORIZONTAL 7 1 2HP 120 GALLON MODEL 775HT12 ...
Page 20: ...CT SERIES CAP 410 PAGE 18 EXPLODED VIEW HORIZONTAL 10HP 120 GALLON MODEL 1075HT12 ...
Page 22: ...CT SERIES CAP 410 PAGE 20 EXPLODED VIEW HORIZONTAL 13HP HONDA ...
Page 24: ...CT SERIES CAP 410 PAGE 22 EXPLODED VIEW HORIZONTAL 13HP KOHLER ENGINE ...