3
Cold Brew Lock
(Factory set to 15º) Press
to select, < or > to select desired setting (CBL 5 or 15),
to set.
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The first setting is within 5 degrees of set
point, next is within 15 degrees of set point for the Ready to Brew message, however it will brew at any temperature.
Master Reset
Press
to display Are You Sure? Then < for Yes, > for No. Brewer factory defaults are then reset.
Service Call
(Phone number Factory set to 1-[800] 000-0000x) Press
to display number and change number or < to move place and EX to exit when
complete This number will be displayed during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code
(Factory set to 1-2-3-4) Press
to display number and change number, (the range is 1 to 4) or < to move place and ex to exit when complete.
Banner Name
(Factory set to McDONALD’S) Press
to display letters and change letters or < to move place and EX to exit when complete. This feature
allows up to 14 letters to be programmed for company name or regional name. Programming all blanks disables Banner Name.
Warmer Auto OFF
(Factory set to Disable) Press
to Select. Press < or > to move to desired time and then
to set. Timer range is OFF, 2 hours, 3 hours,
and 4 hours.
P-Maintenance
(Factory set to OFF) Press
to select. To turn on, press < or > set gallons brewed. The range is from Off to 3000 gallons. Press
to exit.
When the number of brews reaches the set amount, P-Maintenance will display on the screen.
Beeper On/Off
(Factory set to ON) Press
to display ON or OFF. Pressing either < or > to toggle between on and off. Press
to set.
Pulse Brew
(Factory set to Pulse D [1 pulse of 40 sec on, 5 sec off, 2 pulses of 40 sec on, 5 sec off] ). Press
to select, < or > to select OFF or one of five
pulse patterns (A to E) .
Guidelines for Pulse Brew:
This feature allows tuning of the coffee flavor. The pot level should always be set first with this option OFF. Depending on your grind profile and water condi-
tions, the five Pulse Brew options help “tune” or change the coffee flavor. Filter Pack type coffees typically extract better with the A and B pulse setting. Decaf-
feinated coffees typically extract better with the B pulse setting. High-Yield coffees typically extract better with the C pulse setting. Of course, any of the A, B or
C settings may be used to suit your taste profile. There are two additional settings (D and E) that allow you to manually set the ON TIME pulses and OFF TIME.
If Pulse Brew is selected (ON), Cold Brew Lock is set to within 15ºF of set point and Cold Brew Lock disappears from the list of program selections.
When Pulse Brew is ON, Pre-infusion disappears from the list of program selections.
Display Brew Time
(Factory set to ON). Press
to display ON or OFF. Pressing either < or > toggles between on and off. Press
to set. When on, this
feature will appear when the brew button is pressed. The brew time will count down.
Drip-Out Mode
(Factory set to 1 min) Press
to select. Press > to increase time (to a maximum of 5 minutes) or < to decrease the time and turn OFF. Time
counts up in 5 second increments. Press
to set.
Display Messages
(Factory set to ON) Press
to turn ON or OFF. The message displayed is “Rinse Server Before Brewing”. This message will alternate;
two seconds with Rinse Server Before Brewing, then McDONALD’S - READY will appear for six seconds..
Language
(Factory set to English) Pressing < or > toggles between English and French. Press
to set.
Model Select
(Factory set to ALPHA-3/4/5) Press
to select, < or > to select model. The selections are: ALPHA-1, ALPHA-2, ALPHA-3/4/5, Airpot Brewer,
Thermo-Alpha (for the D60GT). Press
to set. When the Model Select feature is changed, all settings are reset to the defaults of the newly selected model.
Exit
Press
to select, exits program mode and returns unit to operation.
Warmer Temperature Control
Turn on brewer at the control panel ON/OFF button. Warmer button should be OFF (LED off). Press and hold desired WARMER button. Screen will display cur-
rent setting in % of power. Press < or > to increase or decrease power to warmer (50% to 100% in 10% increments). Press
to set.
Tank Temperature Check
Turn on brewer at the control panel ON/OFF button. Press and hold
3
button (see illustration, page 2) for 5 seconds. Water Temperature will be displayed. The
temperature will not display while the unit is in the process of reheating.
NOTE: Alpha 3GT ONLY; when checking tank temperature, first make sure REAR warmer is ON (red LED on) and then press button
3
for 5 seconds to
display tank temperature.
Brew Volume – Easy Access
Units can be easily adjusted from the front panel. Written into the software on the Alpha G3 UCM, is a feature to access the brew volume without entering the
program mode.
On any multi-station Alpha (ALP2/3/4/5/6GT): Press the center Select button
2
(see illustration, page 2) twice, with the second press hold down the button for
around five [5] seconds. The screen will display
pressing < or > will adjust the brew volume up or down, ± 20 oz, in 1 ounce increments.