background image

C. Wiring the new controller:

1.

Using the three 13mm bolts retained when the 

original controller was removed, securely fasten 
the four large diameter wires to the new 
controller.

C from motor and CB+ from solenoid.

A1 from motor

CB- from battery

2.

The new controller uses ring terminals instead 

of faston connectors for the field connections.  
Using a wire crimper and the two ring terminals 
(included) cut and re-crimp the black and white 
10awg wires coming from the motor.

3.

Using the supplied M6 bolts, washers, and 

lock washers secure the field terminals to the 
new controller.  The white cable gets 
connected to the F1 connection the black 
cable to the F2 connection.

4.

Insert the conversion harness into the new 

controllers 6 and 24 pin connectors.

5.

Connect the 16 pin conversion harness 

plug and 16 pin original wire harness plug.

62-EZHB-AO WORK INSTRUCTIONS REV. 02 9/14/2018

Reviews: