UNPACKING 

Remove all packaging from the unit. Retain the packaging. If you 

dispose of it please do so according to any local regulations.
The following items are included:

CONTROL PANEL 

PRODUCT OVERVIEW 

It is normal for the heater to emit some smell and fumes when it is turned
on for the first time or when turned on after not being used for a long
period of time. This smell will disappear when the heater has been turned 

on for a short while.

•  Before drilling holes ensure that you will not damage any pipes or 

wiring hidden in the wall.

•  Do not permanently fix the heater to the wall. It is only designed to 

hang from the 2 angle brackets that are attached to the wall.

Ensure you unplug your heater from the mains socket and wait for the 

heater to cool down completely before cleaning.

GB-3

OVERHEAT PROTECTION

 

The power to the heater will automatically cut off if the temperature of the 

heater exceeds a certain limit. In the event of overheating, the heater will 

stop operating. Switch the heater off and allow it to completely cool. The 

heater will then resume operating as normal.

WALL MOUNTING (OPTIONAL)

The heater can also be installed on a wall using the supplied accessories. 

The feet should not be attached to the heater.
1. Drill 2 holes in the wall. Insert the wall plugs. Make sure the mains cable 

can still reach a mains socket.

2. Install 2 angle brackets to the wall using the 4 type B screws.
3. Attach the other 2 angle brackets to the bottom of the heater housing 

using the 4 type A screws. These will act as spacers. Do NOT attach 

these 2 angle brackets to the wall.

4. Lift up the heater and mount it on to the 2 angle brackets that are 

attached to the wall.

ASSEMBLY

Before using the heater, the feet (supplied) must be fitted to the unit. 

Attach the feet to the base of the heater using the 4 type A screws provided 

(2 for each foot), taking care to ensure that they are located correctly in the 

bottom ends of the heaters side moldings.

OPERATION

1. Position the heater upright on the floor away from curtains, furniture or 

wallcoverings before plugging your heater into the mains socket.

2. Press the 

Power Switches

 to the “750W” or “1250W” position. The heater 

has 2 built-in heating elements. You can select one or both heating 

elements simultaneously.

3. Turn the 

Thermostat Control

 to the desired position. It is recommended 

to select the “MAX” position to get the heater to pre-heat. It will take 

5-10 minutes for the heater to fully heat up.

4. When the room reaches the desired temperature, turn the 

Thermostat 

Control

 slowly anti-clockwise until the indicator goes off with a “click” 

sound. The heater will temporarily go off.

5. If the room temperature falls below the desired temperature, the heater 

and indicator will turn on again until the room temperature reaches the 

desired temperature.

CLEANING

Your heater should be cleaned regularly to stop dirt and dust building up 

which will affect its performance. Ensure the air inlet and the air outlet are 

not blocked.
This can be done with a vacuum cleaner, using the brush attachment.

If items are missing or damaged, please contact Partmaster (UK only). 

Tel: 0844 800 3456 for assistance.

The Main Unit

Foot x 2

(P.N.: A007)

Angle Brackets x 4

(P.N.: A008)

The Instruction Manual 

(P.N.: C20CHW10-002)

Screws B (30mm) x 4

(P.N.: A003)

Screws A (15mm) x 4

(P.N.: A002)

Wall Plugs x 4

(P.N.: A001)

CONVECTOR HEATER

INSTRUCTION MANUAL
C20CHW10

Thank You

 for purchasing your new Currys Essentials 

Convector Heater.
We recommend that you spend some time reading this instruction 
manual in order to fully understand all the operational features it offers.
Read all the safety instructions carefully before use and keep this 
instruction manual for future reference.

Air Inlet

Control Panel

Handle

Air Outlet

MIN

MAX

Power Switches  (with Indicators)
750W = Approximately 750W heat output 
1250W = Approximately 1250W heat output
750W+1250W = Approximately 2000W heat 

output

Thermostat Control

Fit the screws in the 

adjacent position

Screw A

at least 600mm

at least 400mm

CEILING

SIDE WALL

GROUND

at least 300mm

Bottom view

Screw B

Screw A

415mm

C

M

Y

CM

MY

CY

CMY

K

C20CHW10_IB_110615.pdf   2   15/06/2011   2:41 PM

Reviews: