background image

FIGURE 1

Pipe Clamp

2b.  Round Pole Architectural Arm

This luminaire has been configured to mount to a round 
poles 2.38 to 6 inches (60-152 mm) in diameter. Hole 
pattern on round pole shall be in  accordance with Figure 2.

WARNING

Under no conditions should architectural  arm mounting bolts 

be torqued to greater than 32 foot pounds (43 N-m)

• Place fixture against pole. Adjust nut plate

(See Figure 3.) to desired hole spacing and tighten set
screw on plate.

• Install 3/8 bolt, lock washer and washer in top hole as

shown and tighten into nut plate. (See Figure 4.)

• Install 3/8 bolt, lock washer and washer below

arm as shown and tighten into nut plate.

• Use 2 inch fender washer provided on bottom bolt for

hole pattern that lines up with keyhole slot (see Figure 5)

• Torque top and bottom bolts to 25 - 32 ft-lbs (34-43 N-m).
• Inspect installation to ensure fixture is secure.

MOUNTING

2

Follow installation instructions for the selected mounting 
method:

a.   Slipfitter

b.  Round Pole Architectural Arm

c.  Square Pole Architectural Arm

d.  Knuckle Slipfitter for 2 3/8 in. (60mm) OD Vertical

Tenon (0 to 45° vertical aiming angle)

2a.  Slipfitter

• The pipe clamp (See Figure 1.) accommodates

1 1/4 inch (1.660 OD) through 2 inch (2.375) O.D. pipe.
Adjust the clamp bolts so the opening is slightly larger
than pipe.

• Insert pipe into back of the luminaire until it contacts

and sits on the center leveling steps extended from
top of housing.

• The luminaire may be leveled by selecting different

steps.

• To level, hold luminaire approximately level and snug

up bolts (4-5 foot-pounds).
— If upward tilt is needed, loosen the bolts slightly, lift

luminaire and shift pipe to the next leveling step.

— If downward tilt is needed, shift pipe to sit on a

more rearward step.

• Once level, tighten each bolt to 10-12 foot-pounds,

alternating between bolts.

• Inspect installation to ensure the fixture is secure.

WARNING

Risk of injury or damage.  Unit will fall if not installed 

 properly.  Follow installation instructions.

• This luminaire has been packed to ensure no damage

during transit. Inspect to confirm.

• Do not impact or stack luminaire after unpacking.

UNPACKING/HANDLING

1

WARNING

Under no conditions should slipfitter bolts be torqued to a 

level greater than 14 foot pounds (19 N-m).

DRILLING TEMPLATE ROUND POLE MOUNTING

2.38 to 6 inch (60 to 152 mm) OD Round Pole Mounting Arm

FIGURE 2

FIGURE 5

FIGURE 4

FIGURE 3

Summary of Contents for Evolve

Page 1: ...vice must accept any interference received including interference that may cause undesired operation This Class A Lighting Equipment complies with Canadian standard ICES 005 A NMB 005 A Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful i...

Page 2: ... 45 vertical aiming angle 2a Slipfitter The pipe clamp See Figure 1 accommodates 1 1 4 inch 1 660 OD through 2 inch 2 375 O D pipe Adjust the clamp bolts so the opening is slightly larger than pipe Insert pipe into back of the luminaire until it contacts and sits on the center leveling steps extended from top of housing The luminaire may be leveled by selecting different steps To level hold lumina...

Page 3: ...12 in 33 mm 4 3920 in 112 mm 2d Knuckle Slipfitter for 2 3 8 in 60mm to 3 0 in 76mm OD Vertical Tenon This luminaire has been configured to provide 0 to 45 vertical aiming in 5 increments and mount on 2 3 8 inch O D 73mm through 3 inch O D 76mm vertical pipe Place slipfitter on the tenon Clamp the fixture to the pipe with three set screws See Figure 6 Tighten set screws to 18 22 foot pounds 24 30 ...

Page 4: ...ion on occupancy sensor behavior with GE LightGrid is available Visit www LED com for more informantion These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered suffi...

Page 5: ...imites ont été établies pour assurer une protection raisonnable contre les interférences nuisibles lorsque l équipement est utilisé dans un environnement commercial Cet équipement produit utilise et peut émettre de l énergie radio électrique et s il n est pas installé et utilisé conformément aux instructions peut provoquer des interférences nuisibles aux communications radio L utilisation de cet é...

Page 6: ...ent plus grande que le diamètre du tuyau qui est utilisé Introduisez le tuyau de montage dans la partie arrière du luminaire jusqu à ce qu il fasse contact avec les gradins de mise au niveau centraux qui font saillie à partir du dessus de bâti et jusqu à ce qu il porte sur ces derniers Le luminaire peut être mis au niveau en choisissant l un ou l autre des différents gradins Pour mettre au niveau ...

Page 7: ...DE SECTION CARRÉE AU GABARIT DE PERÇAGE FIGURE 6 56 mm 2 196 po 11 mm DE DIAM 0 438 po DE DIAM DEUX ENDROITS 133 mm 5 25 po MIN 32 mm DE DIAM 1 25 po DE DIAM TROU 17 mm 0 656 po 33 mm 1 312 po 112 mm 4 392 po 2d Raccord de montage lisse à joint articulé pour tenon de 60 mm 2 3 8 po à 76 mm 3 po de diam ext Ce luminaire a été configuré spécifiquement pour procurer une visée verticale d un angle de ...

Page 8: ...r Le capteur comporte un ensemble distinct de directives de programmation qui est inclus Une documentation complémentaire sur le comportement du capteur de présence avec trame lumineuse est disponible Veuillez visiter LED com pour obtenir de plus amples renseignements à ce sujet Ces instructions ne prétendent pas couvrir tous les détails ou variations de l équipement ni envisager toutes les éventu...

Page 9: ...da Este equipo de iluminación de clase A cumple con la norma canadiense ICES 005 A NMB 005 A Nota Este equipo ha sido probado y cumple con los límites para la Clase A de aparatos digitales conforme a la parte 15 de las Reglas FCC Estos límites están diseñados para proveer protección necesaria para contrarrestar interferencia perjudicial cuando el equipo está en operación en un ambiente comercial E...

Page 10: ...juste los dos pernos de la abrazadera para tubo para que la abertura de la abrazadera sea un poco más grande que el tamaño del tubo que se va a utilizar Inserte el tubo de montaje en la parte posterior de la luminaria hasta que haga contacto y siente en los peldaños de nivelación del centro que se extienden desde la parte superior del gabinete La luminaria se puede nivelar seleccionando peldaños d...

Page 11: ...minaria esté colocada en su posición final PLANTILLA DE PERFORACIÓN PARA EL MONTAJE EN POSTES CUADRADOS FIGURA 6 2 1960 in 56 mm 438 in DIA 11 mm DIA 2 PUNTOS 5 2500 in 133 mm MIN 1 250 in DIA 32 mm DIA ORIFICIO 656 in 17 mm 1 312 in 33 mm 4 3920 in 112 mm 2d Posicionador deslizante de junta articulada para espiga de 2 3 8 in 60 mm a 3 0 in 76 mm de diámetro exterior Esta luminaria se ha configura...

Page 12: ...ón el cual está incluido Está disponible documentación adicional acerca del comportamiento del sensor de ocupación con la rejilla de luz Visite LED com para obtener más información Estas instrucciones no pretenden cubrir todos los detalles o variaciones de equipo ni cada posible contingencia encontrada en conexión a la instalación operación o mantenimiento Si más información es requerida o ciertos...

Reviews: