FIGURE 1
Pipe Clamp
2b. Round Pole Architectural Arm
This luminaire has been configured to mount to a round
poles 2.38 to 6 inches (60-152 mm) in diameter. Hole
pattern on round pole shall be in accordance with Figure 2.
WARNING
Under no conditions should architectural arm mounting bolts
be torqued to greater than 32 foot pounds (43 N-m)
• Place fixture against pole. Adjust nut plate
(See Figure 3.) to desired hole spacing and tighten set
screw on plate.
• Install 3/8 bolt, lock washer and washer in top hole as
shown and tighten into nut plate. (See Figure 4.)
• Install 3/8 bolt, lock washer and washer below
arm as shown and tighten into nut plate.
• Use 2 inch fender washer provided on bottom bolt for
hole pattern that lines up with keyhole slot (see Figure 5)
• Torque top and bottom bolts to 25 - 32 ft-lbs (34-43 N-m).
• Inspect installation to ensure fixture is secure.
MOUNTING
2
Follow installation instructions for the selected mounting
method:
a. Slipfitter
b. Round Pole Architectural Arm
c. Square Pole Architectural Arm
d. Knuckle Slipfitter for 2 3/8 in. (60mm) OD Vertical
Tenon (0 to 45° vertical aiming angle)
2a. Slipfitter
• The pipe clamp (See Figure 1.) accommodates
1 1/4 inch (1.660 OD) through 2 inch (2.375) O.D. pipe.
Adjust the clamp bolts so the opening is slightly larger
than pipe.
• Insert pipe into back of the luminaire until it contacts
and sits on the center leveling steps extended from
top of housing.
• The luminaire may be leveled by selecting different
steps.
• To level, hold luminaire approximately level and snug
up bolts (4-5 foot-pounds).
— If upward tilt is needed, loosen the bolts slightly, lift
luminaire and shift pipe to the next leveling step.
— If downward tilt is needed, shift pipe to sit on a
more rearward step.
• Once level, tighten each bolt to 10-12 foot-pounds,
alternating between bolts.
• Inspect installation to ensure the fixture is secure.
WARNING
Risk of injury or damage. Unit will fall if not installed
properly. Follow installation instructions.
• This luminaire has been packed to ensure no damage
during transit. Inspect to confirm.
• Do not impact or stack luminaire after unpacking.
UNPACKING/HANDLING
1
WARNING
Under no conditions should slipfitter bolts be torqued to a
level greater than 14 foot pounds (19 N-m).
DRILLING TEMPLATE ROUND POLE MOUNTING
2.38 to 6 inch (60 to 152 mm) OD Round Pole Mounting Arm
FIGURE 2
FIGURE 5
FIGURE 4