Current eFlux DC Installation Instructions Download Page 4

  

Pump Maintenance

 

 

Installation Instructions     

 

 

Installation

Page 4

Step 1. Plug DC pump cable into pump connection on manifold HUB.
Step 2. Plug 24VDC power supply into DC input on manifold HUB.

Connecting Pump to Manifold HUB

Step 3. Red LED status light should turn solid red.  Adjust flow from 0-100% using dial until 

 flow rate is acheived.  NOTE: eFlux DC pumps have a slow ramp to speed, allow pump 

 to run for 10-15 seconds for pump to reach adjusted flow.

 **Important - Due to harsh conditions found around marine aquariums, it is important to perform the 

following pump maintenance every 6 months. When performing any maintenance or service, ensure

pump is disconnected from power and manifold HUB.

1. Remove pump from service by disconnecting power and removing pump from sump via disconnect

fittings.

2. Carefully remove front pump cover, o-rings and slide impeller from pump. Use a small soft brush and

running freshwater to clean any organic debris.  If any calcium deposits have developed, soak the

components in mild vinegar/freshwater solution. DO NOT use strong acids.

3. Re-assemble pump, reconnect fittings with all o-rings properly in place and reconnect power.

 Flow Pump 

Manifold HUB

P1

Pump Dial

Flow Control

Pump Power

DC Input

Pump

Connection

Port#1

Port#2

Port#3

Port#4

Important: Before connecting all of the components together, please review the following specifications

in regards to the Flow Pump Manifold HUB and appropriate connections. 

 

Communication LED

Indicator Lights

Specifications:

Pump DC Inputs:

Voltage: 24VDC

Max. DC Input per Channel: 120w@24VDC

Max. DC Output per Channel: 80w@24VDC

Indicator LEDs:

A (Blue)= Indicates 1050 gph pump is connected

B (Blue)= Indicates 1900 gph pump is connected

C (Blue)= Indicates 3170 gph pump is connected

D (Blue)= Feed - flashes when pump is in feed mode

E (Red)= Active feedback/pump status:

 

  Red Solid - indicates pump is operating normal 

 

 

  Red Flashing - indicates non-normal operation

 

 

 

(pump running dry, over voltage

over/under voltage, over temperature)

    MicroUSB Ports

(all for communication)

A

B

C

D

E

AC Power

GFCI Outlet

24VDC

Transformer

  Flow Pump 

Manifold HUB

Connect to Pump Input

Connect to DC Input

To other LOOP

Manifold HUBS

P1

P3

P2

Note: FEED mode will only operate when DC pump is plugged into a manifold HUB with an Orbit IC

 controller, eFlux wave pump controller or the HUB is controlled via Bluetooth.  When in FEED

 mode, DC flow pump will ramp down to 30% flow for 10 minutes, then ramp to normal speed. 