D Electrical connection (qualified electrician’s inspection)
√
For a correct connection during the installation:
•
provide a socket
connecting to the electrical network near the
product.
•
machines
have
the power cable already installed; a plug
(not supplied) must be fitted to it
of suitable capacity.
This operation must be carried out
by qualified personnel.
•
check that the systems in the room comply with the legal
provisions in force in the country of use
and meet the
specifications on the serial number plate. For a correct electrical
connection, the appliance must:
•
be included in an
equipotential system
in compliance
with the legislation in force. This connection must be made
between the various devices with the terminal marked
with the equipotential symbol
. The cable must have
a maximum cross-section of 10 mm
2
(in compliance with
IEC EN 60335-2-42:2003-09) and must be yellow-green;
•
must be
grounded
to the mains (green-yellow wire);
•
must be connected to a
circuit breaker
in compliance with
the regulations in force (0.03A A type);
•
must be connected to an
omnipolar circuit breaker
allowing complete disconnection in overvoltage III category
conditions.
Electrical data
Model
SILEA
Supply
V
kW
Average
consumption
kW/h
Absorbed
current
A
Cable type*
n x mm
2
Cust. panel
prot.
nxA
20
single-phase 230V 50/60Hz
0.75
0.45
3.3
3x1,5
2x16
three-phase 3x230V50/60Hz
0.75
0.45
1.9
4x1,5
3x16
three-phase N 50/60Hz
0.75
0.45
1.1
5x1,5
4x16
30
single-phase 230V 50/60Hz
1.1
0.66
4.8
3x1,5
2x16
three-phase 3x230V50/60Hz
1.1
0.66
1.8
4x1,5
3x16
three-phase N 50/60Hz
1.1
0.66
2.6
5x1,5
4x16
single-phase 208v 50-60Hz
1.1
0.66
5.3
3xAWG16
3x16
three-phase 3x208V50/60Hz
1.9
1.14
5.3
4xAWG16
4x16