32
D
C
A
B
S
R
N
T
4
3
1
2
AC 3 N 400V
AC 3 230V
S
R
T
4
3
1
2
1
2
3
4
C
B
A
A
Fig. 32.
Fig. 33.
Electrical connection
The electrical connection must be carried out
exclusively
by qualified person-
nel after reading the safety warnings at the beginning of the manual.
Before installing the appliance,
check that systems comply with the regula-
tions in force
in the country where it is going to be used and
with the specifi-
cations indicated on the appliance rating plate
on the rh side of the oven.
The appliances have a socket in the back
D
where the supplied plug
C
must be
inserted.
A qualified electrician must fit on the socket
C
:
•
a plug
B
(not supplied)
•
a power cable
A
(not supplied) of adequate capacity and section (see table on the
following pages). It is very important that the power cable is correctly connected to
the connector terminals: to make a correct connection, refer to
Fig. 28
point
4
or
the adhesive located on the back of the oven.
Installation
connector
plug
socket
power
cable