If UPS does not work in case of power failure
UPS l's batteries may be faulty, the cradle may be defective. Talk to your
dealer.
UPS control distance is short. The battery of your controller may be exhausted,
dense electrical cables are passing through the regions close to the antenna of
the UPS, there may be intensity (interference) in the 433 MHz band. Talk to
your dealer. If the shutter works in one direction Motor output ends may be
connected incorrectly.
Straighten the cables The UPS may have malfunctioned due to a bad
connection. Talk to your dealer.
If the shutter does not work in case of power failure
Shutters may be stuck; batteries may be empty. Talk to your dealer.
If the led is not light UPS may not be receiving electricity. The fuse may have
blown.
FAILURE CASES
Technical Specification
Model
: 1100
Power
: 1000 W
Input Voltage
: 220 VAC, 1 phase
Input Frequency
: 50/60 Hz
Output Voltage
: 220 VAC, 1 phase
Output Frequency
Grid Operation Range
RF Operation Frequency
Battery Type
Battery No & Warranty
Charge Period
Standby Period
Remote Controller Range
Alarms & Warnings Indicators
Protection
Operation Temperature
Net & Lifting Weight
Dimensions
Options
: 50/60 Hz
: 170-230 VAC
: 433,92 MHz
: Maintenance free dry type
: 2 pcs 12 V 7 Ah / 2 Year
: 12 hours
: 4 Days (100 Hours)
: 30 Meter
: warning on operation from the battery, no network warning
: Grid Voltage (Line) and Inverter (Battery) warning led
: Excessive load protection, short circuit protection
:
0°C
-
50°C
: 6.4 kg / 160- 220 kg
: 370 x 320 x 150 mm
: External receiver, 42 pieces remote controller