P. INSTALLATION TROUBLESHOOTING
Problem: Leak at the feed water tapping valve.
Cause:
Tapping valve is not clamped tightly enough.
Solution:
Tighten the tapping valve clamp screws evenly and
firmly keeping both halves of the bracket parallel. Be sure not
to deform tubing.
Problem: Leak at the drain saddle.
Cause:
Drain saddle not clamped tightly enough.
Solution:
Tighten the drain saddle screws evenly and firmly.
Problem: Leak at the fittings threaded connection.
Cause:
Fitting is improperly taped or not
tightened sufficiently.
Solution:
Retape the threaded portion with Teflon
®
tape and
thread it in firmly. Do not over tighten.
Problem: Leak at the fitting's push-in connection.
Cause:
Tubing is defective if there is a tubing misassembly.
Solution:
Remove the tubing. Squarely cut off 1/4 inch from
the end of the tubing using a sharp razor knife and reinsert it
into the fitting. Make sure that the tubing is pushed in com-
pletely until it seats.
Problem: Leak at the filter cartridge head.
Cause:
Defective or misaligned O-ring.
Solution:
Close the feed water tapping valve and the storage
tank valve. Lift up on the faucet handle and drain the tank a
minimum of 5 minutes. Remove the filter cartridge and check
the condition of the O-rings. If they are misaligned, reseal
them. If they are damaged, replace them.
Problem: The faucet leaks from the spout with the handle down.
Cause:
An obstructed or defective valve seat in the faucet
mechanism.
Solution:
Remove the faucet spout with a twisting/lifting
motion and slide the faucet handle forward over the spout hole
to gain access to the faucet valve. Unscrew the tee-bar and
the slotted bushing to remove the valve. Clean out any
obstruction or replace it with a new valve mechanism if neces-
sary.
Problem: No steady drip from the open faucet after the
tank is drained.
Causes:
•
The feed water tapping valve is not open.
•
The feed water tapping valve is not installed properly.
•
A leak from any product water fitting connection.
•
The icemaker valve was left open before the start-up
procedure completed.
•
Air is still trapped in the system.
Solutions:
•
Open the feed water tapping valve completely.
•
Check the feed water tapping valve installation to make
sure that the needle has pierced the tubing.
•
Correct the fitting leak as outlined above.
•
Close the icemaker valve and wait until the faucet drips.
•
Wait for the air to be purged from the system.
Problem: Water leaks from air gap module opening.
Causes:
•
The drain line tubing is looped, kinked, or has a low spot.
•
The drain line is blocked or the drain hole is not drilled
through completely.
•
Air is locked in the air gap outlet.
•
There is excessive RO reject flow.
Solutions:
•
Trim any excess tubing to obtain a short, "straight-shot" to
the drain.
•
Check to see that the drain line is clear of any obstruction
and remove the drain saddle fitting to verify that the hole is
drilled through completely.
•
Blow air into the air gap outlet using a short length of tubing.
•
Disconnect the red SFC reject tubing from the faucet air
gap inlet tubing and check the reject flow rate. It should
be less than 175 ml/min. If it is greater than 175 ml/min.,
replace the red SFC reject tubing with the new one of
proper length.
Problem: Too little or no reject flow.
Causes:
•
Red SFC reject tubing is plugged or defective.
•
The feed water tapping valve is not open.
•
An obstruction in the faucet air gap module.
Solutions:
•
Replace the SFC reject tubing with one of proper length.
•
Open the feed water tapping valve completely.
•
Remove the air gap module and inspect the internal flow
path. Replace the air gap module if necessary.
Problem: Chlorine or other unpleasant taste/odor is evi-
dent after the initial tank filling.
Cause:
Residual preservative/sanitizer is still in the water.
Solution:
Drain and fill the storage tank several times if
necessary.
Problem: Noise in the drain (gurgling or
dribbling sound).
Cause:
The reject water is dripping into the standing water in
the drain trap.
Solutions:
•
Make sure that the 3/8" black drain tubing from the faucet
air gap module slopes continuously downward to the drain
saddle without any loops or low spots.
•
Angle the drain piping so that the reject water runs down
the side of the drain pipe.
•
Change the location of the drain saddle to the horizontal
drain pipe or any alternate vertical drain pipe which is
farther from the trap. Properly plug the original hole.
Caution:
Make sure the drain saddle is always installed
above (before) the trap.