Connecting Your JetSort | JetSort
®
1606 interface with JetScan or JetCount | 5
Set Peripheral Device, Baud Rate, Stop Bits and Parity
JetSort has four communication ports. In order to connect a JetScan or JetCount, baud rate, stop
bits and parity must be set. The exact settings for baud rate, stop bits and parity are irrelevant as
long as the JetSort settings match the JetScan or JetCount settings.
Peripheral Device
Device Options
Baud Rate Options
Stop Bits/Parity
Options
JetScan
JtS
600
1200
2400
4800
9600
7, NP
7, Evn
7, Odd
8, NP
8, Evn
8, Odd
JetCount
JtC
JetSort
JETSORT
Set JetSort Communication Ports
1.
Press PRINT to move the cursor to the bottom menu line.
2.
Press TOTALS to scroll to peripheral type: JtS (JetScan) or JtC (JetCount). For more information about
other peripheral types, see the
JetSort 1000 Series Coin Sorter Operating Instructions
.
3.
Press START S/BAT to advance to Baud Rate options.
4.
Press TOTALS to scroll to correct Baud Rate (see table above).
5.
Press START S/BAT to advance to Stop Bits and Parity options.
6.
Press TOTALS to scroll to correct Stop Bits and Parity (see table above).
7.
Press CLEAR to exit.
8.
Connect cable to the programmed port.
PORT 1
SETUP:
JtC
2400, 7, NP