4801-5101 Rev 1-2015
Page
6
of
30
Super Saver XL CE Heater
3. Maintenance
MAINTENANCE
1. This appliance is in compliance with EN 12669 and must be commissioned after servicing.
A qualified installer is required to install, commission, and adjust appliance.
2.
The appliance area should be kept clear & free from combustible materials, gasoline and other
flammable vapors, and liquids.
3.
The flow of combustion and ventilation air must not be obstructed.
4.
Your Super Saver XL Heater should be inspected before each use, and at least annually by a
qualified service person.
5.
Visually inspect gas plumbing to the heater prior to each use. Gas plumbing must be in accordance
with local codes and requirements.
6.
Inspect heater and gas connections periodically for gas leaks with an approved gas leak testing
solution (soap and water work well).
7.
Keep heater clean at all times.
A.
Open doors and blow out dust with high pressure air hose. Be sure interior of
burner and flared end are kept clean.
B.
Burner orifice and hot surface ignition assembly must be kept clean and free of
carbon build-up.
C.
Check blower wheel regularly for dust accumulation and clean periodically for
maximum airflow.
D.
Thermostat coils must be kept clean to assure proper temperature control.
E.
Igniter must be cool before wash down. Do not operate heater for one hour
following wash-down.
Summary of Contents for SUPER-SAVER XL SS-225-XL