4801-5101 Rev 1-2015
Page
12
of
30
Super Saver XL CE Heater
7. Gas/Air Requirements
Table 1: Gas/Air Requirements
Appliance
Gas
Common
Inlet Pressure
Operating
Orifice Dia. (mm)
Conversion Kit
Category Number
Name
(mbar)
Pressure (mbar)
Below 610m
TO
the stated Category
2H, 2E
G20
Natural Gas
20
9.45
9.15
6450-9085
2L
G25
Low Heat Value Nat. Gas
25
14.10
9.15
6450-9085
3B/P
G30/G31
Butane/Propane
30/50
25.00
4.57
6450-9087
3P
G31
Propane
37
25.00
4.69
6450-9086
Appliance
Gas
Flow Rate Combustion Air
Ventilation
CO
2
Limit Air
Cal. Value*
Category
Number
Required (m
3
/hr) Provided (m
3
/h) Required (m
3
/hr)
(MJ/m
3
)
2H,2E
G20
6.28 m
3
/hr
60
1700
238
37.78
2L
G25
7.31 m
3
/hr
60
1700
266
32.49
3B/P
G30/G31
4.8 kg/hr
58
1700
160
125.81
3P
G31
4.71 kg/hr
59
1700
115
95.65
Source: Adopted European Standard EN 437:1993
*Gross Cal. Values, 15°C (59°F ), 1013.25 mbar (406.78 in. w.c.)
8. Conversion To Other Gases
8.1 Tools Required
Adjustable Wrench
Pipe Wrench
Pipe Sealant
Gas Leak Testing Solution
Orifice
Burner
Gas Valve
Ball Valve
F
F
i
i
g
g
u
u
r
r
e
e
9
9
Summary of Contents for SUPER-SAVER XL SS-225-XL
Page 28: ...Copyright 2015 by The GSI Group LLC Printed in the USA ...
Page 29: ......