4. Electrical Wiring
16
PNEG-1559
Competitor Series - Fiberglass Fans
54" 3 Phase 50 Hz CE Electrical Hook-Up
CE Fan Electrical Connections (For 54", 3 Phase, 50 Hz Fiberglass CE
Fans Only.)
1. 3 Phase supply only.
2. Electrical supply protection fuses (not supplied).
3. Motor contactor (not supplied) with fused control voltage via fan control switch or control system
(not supplied).
4. Motor overload breaker (not supplied).
5. Service disconnect (not supplied).
Figure 4C 3 Phase Only
Energize the fan and note the direction of rotation. The prop should turn counterclockwise when viewed
from inside the house. If not switch the L1 lead with either the L2 or L3 and rotation will be corrected upon
re-energizing fan.