![Cumberland AP Cumberland EDGE Installation Manual Download Page 19](http://html1.mh-extra.com/html/cumberland/ap-cumberland-edge/ap-cumberland-edge_installation-manual_2698006019.webp)
3
Basic Connections and Wiring
Topics Covered in this Chapter
Connecting the EDGE Weather Station to Communication Network
Connecting the Wires for the Main Weather Sensor (110WX)
Connecting the Rain Sensor to the Weather Station
Power Source Connections
Before You Begin
• The recommended installation wire gauge is 16 AWG (1.29mm diameter or cross-sectional area of
1.30 mm
2
) for the power supply wires at a length of 300 meters (1000 feet). The minimum wire
gauge is 18 AWG (1.02 mm or cross-sectional area of 0.82 mm
2
).
• When tightening small terminal blocks, use a torque between 0.5 N*m (4.43lbf*in) and 0.6 N*m (5.2
lbf*in) to fasten a wire gauge from 16 AWG to 18 AWG (from a diameter of 1.29 mm or a cross-sec-
tional area of 1.30 mm
2
to a diameter of 1.02 mm or a cross-sectional area of 0.82mm
2
).
• Disconnect supply before servicing.
What You Should Know
1. Locate the
Automation or Safety
terminals on the EDGE Weather Station to connect.
2. Connect the wires (24V and GND) from the EDGE Weather Station to the network.
Consult the wiring diagrams to see the maximum cable distance according to the wire gauge.
IMPORTANT:
Make sure to connect the same identifications together and to use the same network
from one side to the other
IMPORTANT:
If redundancy supplies are not used, use the Automation bus.
WARNING
Installation must only be performed by qualified service personnel.
PNEG-2248
Weather Station
19
Summary of Contents for AP Cumberland EDGE
Page 1: ...EDGE Weather Station Installation Manual PNEG 2248 Version 02 Date 05 12 19 PNEG 2248...
Page 4: ...NOTES 4 PNEG 2248 Weather Station...
Page 10: ...NOTES 10 PNEG 2248 Weather Station...
Page 18: ...NOTES 18 PNEG 2248 Weather Station...
Page 26: ...Chapter 3 Basic Connections and Wiring 26 PNEG 2248 Weather Station...