47
46
Using the Wide Panel
Pull out the wide panel and
place it over the flash head as
shown. The flash coverage will
then be extended to 14 mm.
• The catchlight panel will
come out at the same time.
Push the catchlight panel
back in.
• When pull out the wide panel, the ZOOM will constantly
be 14mm. The <ZOOM> button will not work.
Low Battery Warning
If the battery power is low,
< > will appear and blink on
the LCD panel. Please replace
the battery immediately. When
the low battery indicator is dis-
played, the ZOOM can not be
adjusted, it will constantly be
24mm.
C.Fn: Setting Custom Functions
The following table lists the available and unavailable custom
functions of this flash.
C.Fn Custom Functions
Custom Func-
tion Signs
Function
Setting No.
Settings & De-
scription
ST
Auto sleep
(standby)
ON
ON
OF
OFF
BL
Backlighting
control
10 sec.
Off in 10 sec.
OF
Always off
ON
Always lighting
1. Press the <
ZOOM
> Button for 2 seconds until C.Fn menu is
displayed.
2. Turn the Select Dial to select the Custom Functions.
3. Press the <
SET
> Button and the Setting No. blinks.
4. Turn the Select Dial to set the desired number. Pressing the
<
SET
> Button will confirm the settings.
5. Press the <
ZOOM
> Button to exit.
Protection Function
1. Over-Temperature Protection
• To avoid overheating and deteriorating the flash head, do not fire
more than 30 continuous flashes in fast succession at 1/1 full
power. After 30 continuous flashes, allow a rest time of at least
10 minutes.
• If you fire more than 30 continuous flashes and then fire more
flashes in short intervals, the inner over-temperature protection
function may be activated and make the recycling time over 10
seconds. If this occurs, allow a rest time of about 10 minutes,
and the flash unit will then return to normal.
• When the over-temperature protection is started, is shown on
the LCD panel.
Number of flashes that will activate over-temperature pro-
tection:
Power Output Level
Number of Flashes
1/1
30
1/2 +0.7
40
1/2 +0.3
50
1/2
60
1/4(+0.3,+0.7)
100
1/8(+0.3,+0.7)
200
1/16(+0.3,+0.7)
300
1/32(+0.3,+0.7)
500
1/64(+0.3,+0.7)
1000
1/128(+0.3,+0.7)
Number of flashes that will activate over-temperature pro-
tection in high-speed sync triggering mode:
Power Output
Times
1/1
15
1/2(+0.3,+0.7)
20
1/4(+0.3,+0.7)
30
1/8(+0.3,+0.7)
1/16(+0.3,+0.7)
40
2. Other Protections
The system provides real-time protection to secure the device
and your safety. The following lists prompts for your reference:
Prompts on
LCD Panel
Meaning
E1
A failure occurs on the recycling system so that the flash
cannot fire. Please restart the flash unit. If the problem still
exists, please send this product to a maintenance center.
E2
The voltage on two outlets of the flash tube is too high.
Please send this product to a maintenance center.
E3
There are some errors occurred during the upgrading pro-
cess. Please using the correct firmware upgrade method.
FR36_BDA_Olympus 171005.indd 46-47
06.10.2017 15:11:38