Accessories
29
Cat. No. 01023095
Back of GBE Board
RF Board (note orientation)
Figure 12.
RF board location on GROC board.
7. Install RF board into unit controller. Line up pins in RF board and press firmly into black connectors. Note ori-
power.
8. Follow the directions on the next page to program BOTH the main and remote monitor units to communicate
with each other. If modem has been installed in the remote, it is also necessary to follow the directions in the
next section of this manual to configure the main controller to use the modem in the remote.
Wireless Remote Setup
Begin the wireless setup using the wireless remote device.
RUNNING
JAN-01-12 12:01P
1. From the default home screen, press
. The screen displays the main menu.
1) INFORMATION
>2) SETUP
3) DIAGNOSTICS
2. Press
to select 2)SETUP.
>1) RF SETUP
2) MODEM SETUP
3. Press
to select 1)RF SETUP.
Wireless Remote Settings
Screen Display
Range
Changing the Setting
CHANNEL #
1
1–254
Press
or
and then
to select the channel number of the control
valve. The CHANNEL # for the RO controller must be the same as the CHAN-
NEL # for the Remote Display.
RF FREQUENCY
915 Mhz
433, 869,
or 915
Use this setting to select the correct radio frequency. Do not change the RF fre-
quency for North America installations.