44
Culligan® High Efficiency 1.5 Twin Water Softener
44
Cat. No. 01024821
Inspect/Clean/Replace the Eductor
1. Remove water pressure from the valve.
2. Remove the plastic clip from the upper service
port opening (this port is located on the side of
the valve body, just above the eductor plug). See
3. Remove the eductor plug retainer rod.
4. Remove the eductor cap.
5. Use the notched end of the retainer rod to extract
the eductor assembly from the valve body. Use
moderate pulling force to overcome the O-ring
resistance.
6. Unscrew the eductor filter from the eductor body.
7. Use a small screw driver to extract the eductor
nozzle from inside the eductor body.
Clip
Nozzle
Screen
Throat
Eductor
Cap
Figure 50.
Removing the eductor nozzle and throat.
8. Re-assemble the valve by reversing these instructions. Take care when re-inserting the eductor cap – there is
an arrow molded into the eductor cap. If the cap is installed with the arrow pointing “UP” then the valve is con-
figured for Upflow brining. If the arrow is pointing “DOWN” then the valve is configured for Downflow brining.
Inspect/Clean the Brine Line and Drain Line Flow Control
1. Relieve water pressure from the valve.
2. Remove the cover by releasing the cover fastener from the control (see
).
3. Remove the snap clip which retains the brine line adapter and drain line. (Note that it is easier to do this if you
first remove the wing-screws that retain the HE electronics enclosure.) See Figure 51.
4. Remove the brine line adapter and drain connector.
5. Unscrew the brine line filter from the inner end of the brine line adapter and drain line flow control from the drain
connector.
6. Reassemble by reversing the directions above.
NOTE The number of the flow control should face into the valve body.
Figure 51.
Brine line.
Clips
Flow Control
Drain Elbow
Brine Connector