Average
USEPA
Minimum
Average
Influent
SDWA
2
Reduction
Percent
Percent
Substance
Concentration
MCL (mg/L)
Requirement
Removal
Removal
Arsenic
2
0.03 +/- 10%
0.025
96.6%
98.0%
Barium
10.0+/- 10%
2.0
90.0%
90.0%
Cadmium
0.03 +/- 10%
0.005
90.0%
96.4%
Hexavalent Chromium
0.30 +/- 10%
0.1
86.7%
86.7%
86.6%
Trivalent Chromium
0.30 +/- 10%
0.1
85.7%
85.7%
Copper
3.00 +/- 10%
1.3
96.5%
99.2%
Cysts
6
>50,000/ml
99.95%
99.99%
99.99%
Fluoride
8.0 +/- 10%
1.5
89.8%
95.2%
Lead
0.15 +/- 10%
0.010
97.0%
98.1%
Nitrate plus Nitrite (both as N)
30.0 +\- 10%
10.0
Nitrate
3
27.0 +/- 10%
10.0
74.03%
80.4%
Nitrite
3.0 +/- 10%
1.0
68.3%
75.8%
Radium 226/228
4
25pCi/L +/- 10%
5pCi/L
80.0%
80.0%
Selenium
0.10 +-/10%
0.05
93.02%
96.8%
Product
TDS Reduction
System Daily Prod. Rate
Average Maximum
Average
Prod. Rate w/o Storage
USEPA
Inffluent
Effluent
Minimum
Effluent
Average
Tank
to Pressurized
Tank to
SDWA
Conc.
Conc.
Percent
Conc.
Percent
Size
Storage Tank
Atmosphere
MCL (mg/L)
(mg/L)
(mg/L)
Removal
(mg/L)
Removal
2 gallon
12.8 gpd (48.45L)
30 gpd
187
776
160
79%
112
85.5%
3 gallon
12.1 gpd (45.8L)
30 gpd
187
770
100
87%
70
90.9%
9 gallon
11.7 gpd (44.2L)
30 gpd
187
758
82
89%
65
91.4%
* This is a factory specification for membrane production. Actual production rate and TDS rejection will depend on
temperature, water pressure, TDS level, membrane variation and usage pattern.
TESTING CONDITIONS (Complete Systems)
Temperature:
77°F ± 2°F
pH:
7.5 ± 0.5
Pressure:
50 psi
Turbidity:
< 1 NTU
This system has been tested and shown to operate at its calculated recovery rating under standard test
conditions.
DIMENSIONS
Filter Assembly
7.5” W x 3” D x 16.5” H (20 cm W x 8 cm D x 42 cm H)
Storage Tank
- Standard
9” Diameter x 15” H (23 cm Diameter x 38 cm H)
- Medium
11” Diameter x 15” H (28 cm Diameter x 38 cm H)
- Large
15.5” Diameter x 22” H (40 cm Diameter x 56 cm H)
The
Good Water Machine
models listed above have been tested according to ANSI/NSF Standard 58 for effective
reduction of TDS, arsenic, barium, cadmium, hexavalent and trivalent chromium, copper, cysts, fluoride, lead, radium
226/228 and selenium as verified and substantiated by test data. The concentration of the indicated substances in water
entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the
system as specified in ANSI/NSF 58.
16
1. While testing was performed under standard laboratory conditions, actual performance may vary depending on water pressures, temperatures, and
other substances, which may be found in your water.
2. This system shall only be used for arsenic reduction on chlorinated water supplies containing detectable residual free chlorine.
3. Nitrate units are not certified for nitrate/nitrite reduction in water supplies with a pressure less than 4 psi (280 kPa). A booster pump is strongly
recommended.
4. Based upon testing methods using Barium as a surrogate. All concentrations in pCi.l: pico cutirs/L.
5. United States Environmental Protection Agency (USEPA) Safe Drinking Water Act.
6. Includes Giardia, Lamblia, Entamoeba Histolyca and Cryptosporidium.
SUBSTANCE REMOVAL
1
OUTPUT (Total Dissolved Solids (TDS) Reduction and Output Production