Descaling the CC Basic™
11
Cat. No. 01021819
CC Basic™ units using an RO configuration should rarely need to be descaled.
A unit with the hot water option may require removing any calcium build-up inside the hot tank,
depending on local water conditions and the type of water treatment.
All personnel should be aware of company requirements for their own cleanliness and hygiene when
servicing and sanitizing a unit.
Latex gloves must be used when handling the filters, UV bulb, quartz sleeve or any components that
have contact with the drinking water.
Prepare the CC Basic™ Unit for Descaling
Turn OFF the Hot tank and the feed water line.
1.
Unplug and drain the unit.
2.
Drain water will be hot!
CAUTION!
Remove the POU kit and the Baffle Cap.
3.
Descale the Hot Tank
Mix 1 bag of ScaleKleen (7 oz. bag of non-toxic citric acid-based descaler, Innowave part no. 01-2076) with 1
1.
gallon of hot RO water in a separate container or pitcher. Stir well.
Add red or green food coloring to the solution, in order to make it easier to tell when the solution is
NOTE
completely flushed from the unit.
Pour the solution into the reservoir and allow the solution to fill the Hot tank.
2.
Fill the reservoir the rest of the way with RO water.
3.
Plug in the unit and turn ON the Hot tank switch.
4.
The unit is now live. Take suitable safety precautions.
CAUTION!
Allow the solution in the Hot tank to heat for 5–10 minutes.
5.
Turn OFF the Hot tank and unplug the unit.
6.
Allow the solution to sit in the hot tank for an additional 10–20 minutes.
7.
Drain the unit through the hot tank.
8.
Drain water will be hot!
CAUTION!
Replace the drain plug.
9.
Descaling the CC Basic™