*Approximate initial product flow is based on properly pretreated feed water of 600 ppm TDS as NaCl, 77°F temperature,
225 psig applied pressure, and silt density index below 3 supplying water to atmosphere. Productivity will vary depending
on other feed water conditions.
B-2XL
B-3XL
B-4XL
Dimensional, Pump Assembly
Width - in [mm]
32 [813]
Depth - in [mm]
13 [330]
Height - in [mm]
11 [280]
Dimensional, Module Assembly
Width - in [mm]
42 [1067]
Depth - in [mm]
6 [153]
Height - in [mm]
17 [432]
Unit Connections
Inlet (Tube)
0.5"
Product (Tube)
0.375"
Concentrate (Tube)
0.188"
Electrical
Motor Horsepower (hp) [kW]
3/4 [1.08]
Power Requirement (VAC/Hz/phase)
115/60/1
Full Load Current (amp)
9.0
Hydraulic-Prefilter
Housing Quantity
1
Cartridge Quantity
1
Cartridge Size - (in) [mm]
10 [254]
Cartridge Rating (micron)
5
Hydraulic - RO
RO Housing Quantity
2
3
4
RO Element Quantity
2
3
4
RO Element Length in [mm]
40
40
40
Product Flow gpm [L/min]*
0.80 [3.03]
1.17 [4.43]
1.53 [5.79]
Concentrate Flow gpm [L/min]*
0.80 [3.03]
1.17 [4.43]
1.53 [5.79]
Operating Weight lb [kg]
75 [34]
84 [38]
93 [42]
Recovery (%)*
Design
50
50
50
Minimum
40
40
40
Maximum Feed Pressure psig [kPa]
250 [1723]
Maximum Product Pressure psig [kPa]
40 [275]
Maximum Temperature °F [°C]
100 [38]
Inlet Pressure
Minimum, dynamic psig [kPa]
20 [138]
Maximum, dynamic psig [kPa]
75 [517]
Maximum, static psig [kPa]
100 [689]
Required Inlet Feed Flow gpm [L/min]
1.60 [6.06]
2.34 [8.86]
3.05 [11.54]
Pump Flow @ 225 psi gpm [L/min]
4.0 [15.1]
4.0 [15.1]
4.0 [15.1]
Salt Rejection, Min. Initial (%)
98
98
98
SERIES BXL/BXL PLUS SPECIFICATIONS
SPECIFICATIONS
5
Specifications
MG10 R/O WATER FILTRATION SYSTEM