![Culligan AQUA-CLEER BXL Series Installation And Operating Instructions Manual Download Page 4](http://html.mh-extra.com/html/culligan/aqua-cleer-bxl-series/aqua-cleer-bxl-series_installation-and-operating-instructions-manual_2697801004.webp)
Introduction
Culligan
®
Aqua-Cleer
®
Series BXL and BXL Plus reverse osmosis systems are designed to meet the needs of
applications for high quality water. This manual contains important information about the unit, including informa-
tion needed for installation, operating, and maintenance procedures. A troubleshooting section provides a guide
for quick and accurate problem solving.
In order for the water treatment system to continue to provide high quality water, a thorough understanding of the
system and its operation is required. Review this manual before making any attempt to install, operate or service the
system. Installation or maintenance done on this system by an untrained service person can cause major equipment
or property damage.
This publication is based on information available when approved for printing. Continuing design refinements
could cause changes that may not be included in this publication.
SAFE PRACTICES
Throughout this manual there are paragraphs set off by special headings.
NOTICE: Notice is used to emphasize installation, operation or maintenance information which is important, but
does not present any hazard.
Example: NOTICE:
The nipple must extend no more than 1 inch above the cover plate.
CAUTION
:
Caution is used when failure to follow directions could result in damage to equipment or
property. Example:
CAUTION:
Disassembly while under water pressure can result in flooding.
WARNING
:
Warning is used to indicate a hazard which could cause injury or death if ignored. Example:
WARNING! ELECTRICAL SHOCK HAZARD! UNPLUG THE UNIT BEFORE
REMOVING THE TIMER MECHANISM OR COVER PLATES!
The CAUTION and WARNING paragraphs are not meant to cover all possible conditions and situations that may
occur. It must be understood that common sense, caution, and careful attention are conditions which cannot be
built into the equipment. These MUST be supplied by the personnel installing, operating or maintaining the
system.
Be sure to check and follow the applicable plumbing codes and ordinances when installing this equipment. Local
codes may prohibit the discharge of acid or caustic solutions to drain. An extra solution tank should be used to
neutralize the solution before discharging to drain.
Use protective clothing and proper face or eye protection equipment when handling chemicals or power tools.
SERIAL NUMBERS
The Culligan Series BXL system has two serial number labels, one for the entire plumbing assembly and one for the
RO module assembly. The plumbing assembly serial number label is located on the top right-side of the panel. The
RO module serial number is located on the modules. Do not remove or destroy these serial number labels.
They must be referenced for warranty parts replacement.
REVERSE OSMOSIS
In order to understand reverse osmosis, we must first define osmosis. Osmosis is the passage of a liquid through a
semi-permeable membrane. A semi-permeable membrane is a membrane which allows one component of a solution
2
AQUA-CLEER SERIES BXL AND BXL PLUS