Use and operation
Cubusan CP120
EN-US
23
5 Use and operation
5.1 Function
n
Make sure that sufficient fresh air is supplied to the room. The Cubusan is not a substitute for adequate ventilation
and is not capable of reversing the conversion of oxygen (O
2
) to carbon dioxide (CO
2
) that occurs through breathing
as well as through combustion processes.
At least one full air exchange or more per hour is recommended. This can be as part of a continuous process in-
volving a ventilation system or can be performed manually through correct 'rush airing' (for a maximum of five min-
utes every 30 minutes).
n
The Cubusan with STEREX technology is an effective method of indoor air treatment and is harmless to human
health.
n
This technology is very environmentally friendly as no chemicals are required while the indoor air is being treated
by the Cubusan.
n
The Cubusan contains a plasma generator, which produces a mixture of air and cold atmospheric plasma through
an electrophysical process. This contains various oxygen species, including highly reactive hydroxyl radicals.
These are distributed evenly within the room by the built-in fan and react with the aerosols, killing germs, viruses,
bacteria, and fungal spores contained in the air. The Cubusan is therefore able to eliminate up to 99.99 %* of
microorganisms in the air and thus also helps to remove bad odors.
n
The plasma air mixture generated by the STEREX technology eliminates bacteria, viruses, germs, etc. that are in
the air by 99.99 %. You can therefore be sure that the air in a 50 m² room (with a room height of approx. 2.5 m) will
be cleaned after a short time.
*
The disinfection effect
during continuous operation of the device (>60 min; continuous disinfection) has therefore been
proven to eliminate
up to 99.99 %
of microorganisms in efficacy classes A (native bacteria and fungi) and B (limited viru-
cide, virucidal effect on enveloped viruses) of the RKI list in a test pursuant to EN14476.
5.2 Commissioning
Damage to the device can endanger your safety. Check it for visible damage. Never oper-
ate a damaged device.
The device may only be operated at the specified voltage. Use only the power adapter
supplied.
n
Make sure that all the contents have been delivered and check for any visible damage.
If there is any damage or if any parts are missing from the delivery, contact your retailer or the manufacturer.
1
2
n
Before commissioning, remove all packaging and the protective
film.
n
Place the CUBUSAN on a soft surface with the underside facing
upwards.
n
Slide the supplied mounting aid over the cable of the power plug
and push it together until it clicks into the connection socket of
the CUBUSAN.
n
Remove the mounting aid and turn the CUBUSAN so it is up-
right.
n
Keep the mounting aid, the packaging, and the user manual for
future transport and servicing purposes.
To operate the device at convenient operating times, we also recommend the optional
WLAN connector.