CUBUSAN CP120 Instruction Manual Download Page 8

Use and operation

Cubusan CP120

EN-US

23

5 Use and operation

5.1 Function

n

Make sure that sufficient fresh air is supplied to the room. The Cubusan is not a substitute for adequate ventilation

and is not capable of reversing the conversion of oxygen (O

2

) to carbon dioxide (CO

2

) that occurs through breathing

as well as through combustion processes.
At least one full air exchange or more per hour is recommended. This can be as part of a continuous process in-
volving a ventilation system or can be performed manually through correct 'rush airing' (for a maximum of five min-
utes every 30 minutes).

n

The Cubusan with STEREX technology is an effective method of indoor air treatment and is harmless to human

health.

n

This technology is very environmentally friendly as no chemicals are required while the indoor air is being treated

by the Cubusan.

n

The Cubusan contains a plasma generator, which produces a mixture of air and cold atmospheric plasma through

an electrophysical process. This contains various oxygen species, including highly reactive hydroxyl radicals.
These are distributed evenly within the room by the built-in fan and react with the aerosols, killing germs, viruses,
bacteria, and fungal spores contained in the air. The Cubusan is therefore able to eliminate up to 99.99 %* of
microorganisms in the air and thus also helps to remove bad odors.

n

The plasma air mixture generated by the STEREX technology eliminates bacteria, viruses, germs, etc. that are in

the air by 99.99 %. You can therefore be sure that the air in a 50 m² room (with a room height of approx. 2.5 m) will
be cleaned after a short time.

*

The disinfection effect

 during continuous operation of the device (>60 min; continuous disinfection) has therefore been

proven to eliminate 

up to 99.99 %

 of microorganisms in efficacy classes A (native bacteria and fungi) and B (limited viru-

cide, virucidal effect on enveloped viruses) of the RKI list in a test pursuant to EN14476.

5.2 Commissioning

Damage to the device can endanger your safety. Check it for visible damage. Never oper-
ate a damaged device.
The device may only be operated at the specified voltage. Use only the power adapter
supplied.

n

Make sure that all the contents have been delivered and check for any visible damage.

If there is any damage or if any parts are missing from the delivery, contact your retailer or the manufacturer.

1

2

n

Before commissioning, remove all packaging and the protective

film.

n

Place the CUBUSAN on a soft surface with the underside facing

upwards.

n

Slide the supplied mounting aid over the cable of the power plug

and push it together until it clicks into the connection socket of
the CUBUSAN.

n

Remove the mounting aid and turn the CUBUSAN so it is up-

right.

n

Keep the mounting aid, the packaging, and the user manual for

future transport and servicing purposes.

To operate the device at convenient operating times, we also recommend the optional
WLAN connector.

Summary of Contents for CP120

Page 1: ...Cubusan CP120 Instruction manual EN US 78 560 014 25 11 2021 ...

Page 2: ...ns 21 4 3 Safety instructions for transportation 21 4 4 Safety instructions for maintenance servicing and troubleshooting 21 4 5 Storage 22 4 6 Views and design 22 5 Use and operation 23 5 1 Function 23 5 2 Commissioning 23 5 3 Site selection 24 5 4 Operation 24 6 Care and maintenance 25 6 1 Care 25 6 2 Inspection refresh by the manufacturer 25 6 3 Clearing faults 25 7 Appendix 27 7 1 Technical da...

Page 3: ...to exercise industrial property rights 1 1 Note on use We expressly point out that the use of the Cubusan is only complementary to an effective hygiene concept and does not replace other hygiene measures When using the Cubusan always observe the manufacturer s instructions for use and the specified minimum square me ters per person without exception In particular WINTERSTEIGER shall not be liable ...

Page 4: ...perating maintenance and service stipulations set out by the manufac turer The applicable accident prevention regulations and other generally accepted safety and occupational health regulations shall also be adhered to Any changes to the device by the user renders manufacturer liability null and void with regards to any resulting damages We constantly try to improve our products and therefore rese...

Page 5: ...medium degree of risk which if not prevented could cause death or serious injury CAUTION describes a hazard with a low degree of risk which if not prevented could re sult in a slight or moderate injury This symbol indicates special information on practical work or a general recommendation Device damage This symbol indicates possible damage to destruction of the product the process and or its surro...

Page 6: ... 2 General safety instructions n The device must not come into contact with water or excessive moisture during operation or storage see chapt Technical data page 27 n Any applicable accident prevention specifications and other generally accepted safety and medical regulations are to be obeyed n The device may only be used if it is in a flawless technical condition and only according to the intende...

Page 7: ...tems and may per form work on them 4 5 Storage n Devices and components must not be stored outdoors n Store the device in its original packaging inside a building only at a temperature of 5 C to 30 C and a maximum relative humidity of 60 To avoid damage never place any other packages or items on top of the packaged unit 4 6 Views and design 1 2 3 4 5 Front view Underside 6 7 8 1 Air outlet 5 Fixin...

Page 8: ... n The plasma air mixture generated by the STEREX technology eliminates bacteria viruses germs etc that are in the air by 99 99 You can therefore be sure that the air in a 50 m room with a room height of approx 2 5 m will be cleaned after a short time The disinfection effect during continuous operation of the device 60 min continuous disinfection has therefore been proven to eliminate up to 99 99 ...

Page 9: ... even the distribution For high rooms rooms over 120 m or rooms with strong ventilation the use of several air purifiers may be necessary We recommend discussing this with the manufacturer The air exchange per hour should not be more than 4 times the air in the room 5 4 Operation The CUBUSAN has several openings slits for the air inlet air outlet which must not be covered under any circumstances M...

Page 10: ...mmend that the plasma unit is in spected refreshed by the manufacturer after 25 000 operating hours with average use 8 hrs day x 365 days 25 000 hrs 8 5 years Depending on the operating environment and especially when the device is used in ex treme conditions the performance of the STEREX plasma unit may reduce in a shorter time than originally anticipated If there is no longer any noticeable air ...

Page 11: ...d that there are no foreign bodies at in the air outlet at the top all round the de vice Device is being operated in a location that does not comply with the specifi cations Position the device in a suitable location see chapt Site selection page 24 Fan defective Have the device checked repaired by the manufacturer 4 Odor in room Insufficient supply of fresh air to the room Increase the fresh air ...

Page 12: ...e electrical and electronic equipment WEEE this device must not be disposed of with household waste Similarly this also applies to countries outside the EU according to the applicable national regula tions n Dispose of this device in accordance with local regulations in a separate collection for electrical and electronic equipment If you have any questions please contact the relevant authority or ...

Page 13: ...Appendix 28 EN US Cubusan CP120 ...