background image

the user. Configure Link Alarm DIP 

switch as “Enabled” status, it 

provides  users  transparent  link  indication  between  two  network 
devices interconnected by WAC-2012. 
 
If Link Alarm is disabled, the UTP and fiber port will link up based 
on their individual linking condition. Furthermore, if the fiber port 
link  is  down  during  the  operation,  the  UTP  port  link  will  not  be 
turned into the “Down” status, and vice versa. 

7.  LED Description

 

8.  Technical Specifications 

Standards 

IEEE 802.3, 802.3u 

Interface 

1 X 10/100Base-TX RJ-45 connector 
1 X 100Base-FX SC/ST F/O port or SFP slot  

LED 

PWR, PW T1, PW T2, FDX, Speed, TP Link/ACT, 
F/O Link/ACT, and PWR/Port Status 

Power 

DC Input Voltage: 12~48V DC, 
AC-DC 12V Power Jack x 1, 
DC Power Input x 2 on Terminal Block  

Power 
Consumption 

2.88W (Max.) 

Shipping Weight 

0.295KG  

Dimensions 

105mm(W)X93mm(D)X35mm(H) 

Temperature 

Operating: -20

º

C~60

º

Storage: -20

º

C~70

º

Humidity 

5%~90% RH non-condensing 

EMC Safety 

FCC Part 15 Class A, CE 

Media 

TP: 

Cat. 5 UTP cable 

 

Fiber: 

50/125, 62.5/125

m multi-mode fiber 

 

 

9/125

m single-mode fiber 

*Please contact us for further reports and updates. 

9.  Fiber Transceiver Information 

100M Multi-Mode:

 

TYPE 

BTFC 

BTFT 

Connector Type 

SC 

ST 

Wavelength 

1310nm 

1310nm 

Typical Distance 

2Km 

2Km 

Min/Max TX PWR 

-20.0dBm/-14.0dBm -20.0dBm/-14.0dBm 

Sensitivity 

-31.0dBm 

-31.0dBm 

Link Budget 

11.0dB 

11.0dB 

100M Single-Mode: 

TYPE 

BTFC(SM-30)  BTFC(SM-50)  BTFC(SM-80) BTFC(SM-100) 

Connector Type 

SC 

SC 

SC 

SC 

Wavelength 

1310nm 

1310nm 

1310nm 

1550nm 

Typical 
Distance 

30Km 

50Km 

80Km 

100Km 

Min TX PWR 

-15.0dBm 

-5.0dBm 

0dBm 

-5.0dBm 

Max TX PWR 

-8.0dBm 

0dBm 

5.0dBm 

0dBm 

Sensitivity 

-34.0dBm 

-35.0dBm 

-36.0dBm 

-35.0dBm 

Link Budget 

19.0dB 

30.0dB 

36.0dB 

30.0dB 

100M Wave-Length WDM: 

TYPE 

W2A(SM-20) 

W2B(SM-20)  W2A(SM-40)  W2B(SM-40) 

Connector Type 

SC 

SC 

SC 

SC 

TX Wavelength 

1310nm 

1550nm 

1310nm 

1550nm 

RX Wavelength 

1550nm 

1310nm 

1550nm 

1310nm 

Typical Distance 

20 Km 

20 Km 

40 Km 

40 Km 

Min TX PWR 

-14.0dBm 

-14.0dBm 

-8.0dBm 

-8.0dBm 

Max TX PWR 

-8.0dBm 

-8.0dBm 

0dBm 

0dBm 

Sensitivity 

-31.0dBm 

-31.0dBm 

-34.0dBm 

-34.0dBm 

Link Budget 

17.0 dB 

17.0 dB 

26.0 dB 

26.0 dB 

NOTE: 

Specifications may change without prior notice.

 

Contact Information 

Connection Technology Systems INC (CTS)  
18F-6, No.79, Sec.1, Xintai 5th Rd., Xizhi Dist., 
New Taipei City 221, TAIWAN, R.O.C.

 

TEL: +886 2 26989661  FAX: +886 2 26989662 
E-Mail: [email protected]

 

 

 

 
 

 

 

 
 
 

WAC-2012 SERIES 

 
 

10/100Base-TX to 

100Base-FX Fast Ethernet 

Media Converter  

 
 
 
 
 
 
 
 
 

User’s Guide 

 

Version 2.0

 

 

LED 

Color 

Function 

PWR 

Green 

Lit when

 

power is available. 

PW T1 

Green 

Lit when TB1 on Terminal Block powers up. 

PW T2 

Green 

Lit when TB2 on Terminal Block powers up. 

TP 

Link/ACT 

Green  

Lit when TP port link is up. 
Blinking when TP port is receiving and transmitting 
data. 
Off when TP port link is down. 

Orange 

Blinking when the port link down caused by Fiber port 
in case Link Alarm is enabled.  

Speed 

Green 

Lit when TP 100M port link is up. 
Off when TP 10M port link is up or no port link exists. 

FDX 

Green 

Lit when TP port works in full-duplex mode. 
Off when TP port works in half-duplex mode. 

F/O 

Link/ACT 

Green 

Lit when Fiber port link is up. 
Blinking when Fiber port is receiving and transmitting 
data. 
Off when Fiber port link is down. 

Orange 

Blinking when the port link down caused by TP port in 
case Link Alarm is enabled.  

PWR/Port 

Status 

Orange 

Lit when TP/Fiber port link is down and two power 
sources are available, or TP/Fiber port link is down 
and only one power source is available. (This 
indication only works when PIN 8 and PIN 9 on the DIP 
Switch are set to “Enable”.) 

Blinking when the redundancy system works 
abnormally (only one power source is available) and 
port links work normally. 

Off when two power sources are available and port 
links work normally. 

Reviews: