8/16
Logika - use and maintenance guide
page
E0
= Cylinder full. It is not possible to recover gas.
E1
= Excessive quantity of gas programmed for recovery.
E2
= Recovery time expired.
E3
= Pressure present in the system at the start or during the vacuum cycle.
E4
= Time to achieve vacuum expired.
E5
= Leaks found in vacuum control cycle.
E6
= Insufficient quantity of refrigerant for programmed charge.
E7
= Refrigerant/oil charge time expired.
E9
= Insufficient quantity of oil injection.
Possible error codes:
7. Menu structure
Whole gas
recovered.
End
operation
0000
End
operation
0000
End
operation
0000
End
operation
WEIGHT
RECOVERY
VACUUM
CHARGING
AUTOMATIC
AUTO
1800
OIL
OIL
SEL
OK
OK
OK
OK
OK
OK
E1
E2
T200
T60
E3
E4
E5
T300
0030
00.70
GAS
00.70
GAS
0030
E6
E7
E9
OIL IN
GAS IN
RECOVERY
AUTO
CHARGING
VACUUM
1800