CTM Marine Self-Contained CT Installation & User Manual
12
Base Pan
Figure 4
Mounting Bracket
Mounting Brackets
Base Pan
Mounting Bracket
Mounting Brackets
Figure 3
Non-Slip Isolation Tape
Attached To Base Pan
Figure 5
5/8" Marine Grade Reinforced Hose
Stainless Steel Hose Clamp
5/8" Hose Barb
Base Drain Pan
Thread Seal Tape
Non-Slip Isolation Vibration Tape
Your a/c unit comes with a separate non-slip isolator tape design to dampen the vibration caused by
the operating a/c unit. Proceed to place the tape on the base of the A/C unit securely. See figure 3.
Condensate Drains
Place the 2 hose barbs (supplied) in their respective drain holes on the base pan. Secure the drain
hose with a stainless steel hose clamp. Route drain hose to a proper collection point. See figure 5.
!
Once this tape is installed care must be taken when moving the a/c unit across mounting surfaces as
the tape can be damaged if excessive dragging occurs.
CARBON MONOXIDE HAZARD
Do not terminate condensate drain lines within three feet (91 cm) of any outlet of engine or generator exhaust
systems, nor in a compartment housing an engine or generator, nor in a bilge, unless the drain is connected
properly to a sealed condensate or shower pump.
Mounting Brackets
The four mounting brackets provided should be placed around edge of drain pan as equally spaced
as possible. Secure a/c unit to a flat level mounting surface. Brackets are provided. Customer is to
supply the necessary hardware such as screw/bolts, and washers. See Figure 4.
Follow each one of the steps as explained on this manual, any deviation from the procedure
explained herein constitutes improper installation of the unit and therefore waives and forever
discharges CTM Marine and its subsidiaries from any liability in connection to the installation;
use; and functioning of the unit and any and all systems and parts connected to it.