1 2 3 4
ON
OFF
1.
Set slide switch 4 to the ON-
position (This is inside the
sensor. The factory setting is
at the OFF-position).
2.
Shortly press the control
button on the front of the
sensor. The sensor now
gives a beep about every two
seconds.
3.
Point the sensor against
your forehead. The unit
will now turn off, since the
temperature registered is
higher than 30°C.
4.
Point the sensor against
cold cooktop or other
cool surface. The unit will
now turn on, since the
temperature registered is
lower again.
To ensure that the function of the Mkomfy
stove guard is in order, it is recommended
that the following test of the product and
the communication is performed:
If a step does not work as described, see the page for various
alarm situations, or visit
www.ctmlyng.no/komfyrvakt
for more
information.
If everything works ... You have now tested that the sensor,
communication and outlet are working properly.
Further testing is not required.
NB! Set slide switch 4 back to the OFF-position, before
attaching the back cover, and reinstall the sensor (see
installation instructions)
Control button
Beeper
Sensor
Test procedure
Sensor
Slide switch