Network Terminal Installation, Operation, and Maintenance Instructions
P/N 8040375G001
4-7
C
HELIX TECHNOLOGY CORPORATION
-
TI
CRYOGENICS
Cryopump on a roughing manifold and they are to be put through a
FastRegen, then they must all be started and run at the same time so that
they can all be roughed at the same time. This also means that if there is a
Cryopump in the process of FastRegen, then no other Cryopump on that
roughing manifold can start a FastRegen until that Cryopump is finished.
This is not true for Full regeneration. Full regenerations can be started and
stopped at any time, even if another pump on the same roughing map is in
regeneration.
Setting up Regeneration Groups with the Network Terminal
1. Press REGEN 9 9.
2. Display reads 1-MULTI PUMP RGN.
3. Press Next. The display reads 1=GROUP SELECT.
4. Press Next. The display reads 1-MULTI.
5. Press Enter. The display reads 1-MULTI and shows which pumps,
if any, are currently in that group. You may have to press the right scroll
arrow > to move the display so that all pumps in that group can be
seen.
6. To change the group, press Enter. All pumps in group 1 are
removed and a new program can be entered into group 1.
7. Enter the 2-digit number of one of the pumps you want in group 1.
8. Press Enter to accept that pump number, or press Clear to remove
that number.
9. Enter the next number for that group, etc.
10. When all of the pump numbers have been entered, press Enter one
more time and the display will go to group 2 and display all of the
pumps in that group.
NOTE: Up to 20 pumps (that is, all the pumps on the network) can be put
into a single group or as few as one pump .
11. To select another group, press Next until the desired group is
reached and press Enter to begin programming.
12. Press Last to return to where you can start a regeneration (see Start-
ing a Group Regeneration).