Connecting the provided cables with eyelet terminals:

Make sure that the cable is not being pinched or in contact with warm surfaces or sharp edges. When the cable 

is mounted on the battery, it should not be connected to the charger. Connect the eyelet terminals to the battery's 

poles - the red cable to the positive pole and the black cable to the negative pole. After this, the quick contact can 

be connected.

Reverse Polarity Protection

If the battery cables are connected incorrectly, the reverse polarity protection will make sure that the charger and 

the battery are not damaged. In this case, the red warning lamp (0) will be lit. 

Start charging

1.  Set the proper charging mode for the battery by pushing the Mode button until the correct setting is lit. Choosing 

settings for your battery is described under ”BATTERY TYPES AND SETTINGS”.

2.  When you are sure the battery leads are correctly placed, connect the power cord to the power outlet to begin 

charging. If the battery leads are wrongly connected, the pole-changing switch will ensure the battery and char-

ger are not damaged. The fault indicator   will light. In which case start from the beginning again.

3.  The charging lamp 

 will now indicate charging or the maintenance lamp 

 will indicate that the battery is 

fully charged. If the voltage drops the charger sends a pulse to the battery. The length of the pulse depends on 

how much the voltage has dropped. The charger can be connected for months.

4.  If nothing happens: If the voltage indicator is lit but no other lamp is lit there could be a bad connection to the 

battery or chassis or the battery could be faulty. Check the wall power outlet. If you experience problems: start 

with the sensitive connection between the battery clamps and the charger.

5.  Charging can be stopped at any time by disconnecting the supply cord or by setting the charger on Standby. 

Always remove the power cord from the power outlet before disconnecting the battery leads from a battery in a 

vehicle. When you stop charging a battery in a vehicle, remove the cable from the chassis before removing the 

other cable.

6. If the charger lamp and the maintenance-charger lamp are flashing alternately, the reason for this is due to:

•  An interruption during charging, due to a loose connection or because the battery has ceased to work.

•  The battery has become sulphated. If the lamps flash for more than 30 minutes, this indicates that the battery is 

dead and needs to be replaced.

•  If there is an interval of more than 10 seconds between the flashes, this indicates that the battery has a high 

self-discharge rate and may need to be replaced.

Summary of Contents for MULTI XS 3600

Page 1: ...MULTI XS 3600 Battery charger For lead acid batteries 1 2 120Ah User s Manual and a guide to professional battery charging For Starter Deep Cycle batteries EN ...

Page 2: ... charge a frozen battery Never charge a damaged battery Do not place the charger on the battery while charging The electrical connection must fulfil the national heavy current requirements Check the cabling in the charger before use Make sure there are no cracks in the cabling or in the protective covering A charger with damaged cables may not be used Always check that the charger has gone over to...

Page 3: ...ture at times exceeds 5 C In this case the 14 4V 3 6A mode is recommended CHARGING Charging batteries mounted in a vehicle 1 The power cord should be disconnected before connecting or disconnecting the battery leads 2 Identify the pole that is grounded attached to the chassis Ground is normally connected to the negative terminal 3 Charging a negatively grounded battery Connect the red wire to the ...

Page 4: ... or the maintenance lamp will indicate that the battery is fully charged If the voltage drops the charger sends a pulse to the battery The length of the pulse depends on how much the voltage has dropped The charger can be connected for months 4 If nothing happens If the voltage indicator is lit but no other lamp is lit there could be a bad connection to the battery or chassis or the battery could ...

Page 5: ...s and the voltage is kept constant at the maxi mum level Pulse Maintenance phase where the charger delivers a pulse if the battery voltage drops Charging varies be tween 95 and 100 The battery receives a pulse when the voltage reduces Keep the battery in good condition when not in use The charger can be connected for months TEMPERATURE PROTECTION MULTI XS 3600 is protected from being overheated Th...

Page 6: ...NICAL SPECIFICATION Model MULTI XS 3600 Voltage AC 220 240VAC 50 60Hz Back current drain 1mA Voltage Charging Voltage Nominal 12V 14 4V 14 7V Ripple Max 50mV rms max 0 13A Current 0 8A 3 6A Ambient Temperature 20 C to 50 C power is reduced automatically at increased ambient temperature Cooling Natural convection Charging cycle MULTI XS 3600 is a multistage fully automatic charger Type of batteries...

Page 7: ...llowing EMC standards EN55011 EN 61000 3 3 EN 61000 3 2 EN55014 1 and EN55014 2 according to the terms of directive 89 336 EEC with the addition of 92 31 EEC and 93 68 EEC The charger comes in different models with different types of electrical plugs The charger with the flat eurocontact is intended for Switzerland VIKMANSHYTTAN SWEDEN 2006 01 23 Börje Maleus VD CTEK SWEDEN AB Rostugnsvägen 3 776 ...