CTEK MULTI XS 3600 User Manual Download Page 2

INTRODUCTION 

Congratulations on your purchase of your new professional MULTI XS 3600 Switch Mode Charger with Pulse 

Maintenance. MULTI XS 3600 is a member of a family of professional chargers from CTEK Sweden AB. It repre-

sents the state-of-the-art technology for battery charging. A MULTI XS 3600 will prolong the lifetime of your battery. 

Read this user manual and follow the instructions carefully before using the charger.

SAFETY

•  The charger is designed for lead-acid batteries from 1,2-120Ah. Do not use the charger for any other purpose.

•  Use safety glasses and turn your head away when connecting or disconnecting a battery.

•  Battery acid is corosive. Rinse immediately with water if acid comes into contact with skin or eyes. Seek medi-

cal advice.

•  Make sure that the cable is not being pinched or in contact with warm surfaces or sharp edges.

•  While charging, a battery can emit explosive gases, so it is important to avoid sparks in the immediate area.

•  Always provide for proper ventilation during charging.

•  Avoid covering the charger. 

•  Make sure that the electrical cable does not come into contact with water. 

•  Never charge a frozen battery.

•  Never charge a damaged battery.

•  Do not place the charger on the battery while charging.

•  The electrical connection must fulfil the national heavy current requirements. 

•  Check the cabling in the charger before use. Make sure there are no cracks in the cabling or in the protective 

covering. A charger with damaged cables may not be used.

•  Always check that the charger has gone over to maintenance charging mode before leaving the charger unat-

tended and connected for long periods. If the charger had not gone over to maintenance charging within 3 days, 

this is an indication of a problem. In this case the charger must be disconnected manually.

•  All batteries fail sooner or later. A battery that fails during charging is normally taken care of by the chargers 

advanced control, but certain uncommon errors in the battery can still arise. Don’t leave the battery charger 

unattended for a longer period of time.

•  Only mount the charger on a flat surface.

•  This equipment may not be used by children or by those who can not read and understand the manual if they 

are not supervised by a responsible person who can guarantee that the battery charger is being used in a safe 

manner. Store and use the battery charger out of the reach of children. Make sure that children do not play with 

the battery charger. 

Summary of Contents for MULTI XS 3600

Page 1: ...MULTI XS 3600 Battery charger For lead acid batteries 1 2 120Ah User s Manual and a guide to professional battery charging For Starter Deep Cycle batteries EN ...

Page 2: ... charge a frozen battery Never charge a damaged battery Do not place the charger on the battery while charging The electrical connection must fulfil the national heavy current requirements Check the cabling in the charger before use Make sure there are no cracks in the cabling or in the protective covering A charger with damaged cables may not be used Always check that the charger has gone over to...

Page 3: ...ture at times exceeds 5 C In this case the 14 4V 3 6A mode is recommended CHARGING Charging batteries mounted in a vehicle 1 The power cord should be disconnected before connecting or disconnecting the battery leads 2 Identify the pole that is grounded attached to the chassis Ground is normally connected to the negative terminal 3 Charging a negatively grounded battery Connect the red wire to the ...

Page 4: ... or the maintenance lamp will indicate that the battery is fully charged If the voltage drops the charger sends a pulse to the battery The length of the pulse depends on how much the voltage has dropped The charger can be connected for months 4 If nothing happens If the voltage indicator is lit but no other lamp is lit there could be a bad connection to the battery or chassis or the battery could ...

Page 5: ...s and the voltage is kept constant at the maxi mum level Pulse Maintenance phase where the charger delivers a pulse if the battery voltage drops Charging varies be tween 95 and 100 The battery receives a pulse when the voltage reduces Keep the battery in good condition when not in use The charger can be connected for months TEMPERATURE PROTECTION MULTI XS 3600 is protected from being overheated Th...

Page 6: ...NICAL SPECIFICATION Model MULTI XS 3600 Voltage AC 220 240VAC 50 60Hz Back current drain 1mA Voltage Charging Voltage Nominal 12V 14 4V 14 7V Ripple Max 50mV rms max 0 13A Current 0 8A 3 6A Ambient Temperature 20 C to 50 C power is reduced automatically at increased ambient temperature Cooling Natural convection Charging cycle MULTI XS 3600 is a multistage fully automatic charger Type of batteries...

Page 7: ...llowing EMC standards EN55011 EN 61000 3 3 EN 61000 3 2 EN55014 1 and EN55014 2 according to the terms of directive 89 336 EEC with the addition of 92 31 EEC and 93 68 EEC The charger comes in different models with different types of electrical plugs The charger with the flat eurocontact is intended for Switzerland VIKMANSHYTTAN SWEDEN 2006 01 23 Börje Maleus VD CTEK SWEDEN AB Rostugnsvägen 3 776 ...

Reviews: