TECHNICAL SPECIFICATIONS
Charger model
US 0.8 (1064)
Model number
1064
Rated Voltage AC
110–120VAC, 50–60Hz
Charging voltage
14.4V
Start voltage
2.0V
Charging current
0.8A
Current, mains
0.3A rms (at full charging current)
Back current drain*
<1Ah/month
Ripple**
<4% of rated current
Ambient temperature
-4°F to +122°F (-20˚C to +50˚C), output power is reduced automatically at high temperatures
Charger type
Six step, fully automatic charging cycle
Battery types
All types of 12V lead-acid batteries (WET, MF, Ca/Ca, AGM and GEL)
Battery capacity
1.2–32Ah, up to 100Ah for maintenance
Dimensions
5½ x 2 x 1½ inch (L x W x H)
Weight
1 lbs
*) Back current drain is the current that drains the battery if the charger is not connected to the mains. CTEK chargers has a very
low back current.
**) The quality of the charging voltage and charging current is very important. A high current ripple heats up the battery which
has an aging effect on the positive electrode. High voltage ripple could harm other equipment that is connected to the battery.
CTEK battery chargers produce very clean voltage and current with low ripple.