![CTE B-LIFT 18 HV Instructions For Use And Maintenance Manual Download Page 112](http://html1.mh-extra.com/html/cte/b-lift-18-hv/b-lift-18-hv_instructions-for-use-and-maintenance-manual_2693671112.webp)
4
Aerial work platform
B-LIFT 18 HV
COD. UM0287_GB | REV. 00 | ED: 09/18
GB
Chapter 12
TROUBLESHOOTING
12.2
List of alarms
The alarm errors and messages are displayed through a sequence of LEDs, ALARM1 (Fig. 12.1, 7)
and ALARM2 (Fig. 12.1, 6).
Example:
spieAlarm_inceppDiscesa = 0 x 0803
08 = 8 lashes of LED ALARM1
03 = 3 lashes of LED ALARM2
9
8
5
4
3
2
1
7
6
Fig.
12.1
Alarm code
Description
ALARM1
ALARM2
CAN ALARM
0x
01
01
spieAlarm_MMSSafetyNoCan
02
spieAlarm_MMSTorr1NoCan
03
spieAlarm_MMSTorr2NoCan
04
spieAlarm_MMSCestelloNoCan
05
spieAlarm_MMSPulsCarroNoCan
06
spieAlarm_MMSSafetyNoGND
07
spieAlarm_MMSTorr1NoGND
08
spieAlarm_MMSTorr2NoGND
Alarm code
Description
ALARM1
ALARM2
SENSORS ERROR ALARM TORR 1
0x
02
01
spieAlarm_angRotTorr1Cks
02
spieAlarm_angRotTorr1Open
03
spieAlarm_angRotTorr1VBat
04
spieAlarm_angBraccioTorr1Cks
05
spieAlarm_angBraccioTorr1Open
06
spieAlarm_angBraccioTorr1VBat
07
spieAlarm_pressPistoneTorr1Open
08
spieAlarm_pressPistoneTorr1VBat
09
spieAlarm_pressSteloTorr1Open