Palleon Mobile is in version : Low pressure (15 bar maxi). 
The output of the system Palleon is 30 l/min. 
This model comply with EN 16327 classification. 

 

 
> Operating ranges: See operating curves in page 6. 

General presentation 

Description of the system 

 

Palleon  is  a  single-point  pressurized  injection  device  compliant  with  the  requirements  of      
EN 16327. 

 

 

Palleon can be used with soft water or seawater. 

 

 

Palleon  is  designed  to  be  installed  on  fire  trucks  used  under  normal  operating  conditions 
(outdoors, tunnel, etc.). Explosive atmospheres must be avoided. 

 

 

Palleon operates within a temperature range of - 15°C and + 60°C with a humidity level bet-
ween 30 and 90%. 

 

 

CTD recommends the use of gloves compliant with DIN EN 659 when using a Palleon device. 

 
 

Summary of Contents for PALLEON MOBILE

Page 1: ...Version 1 19 10 16 Fire fighting PALLEON Range USER MANUAL PALLEON MOBILE...

Page 2: ...2 Date Version Modification N pages modified 19 10 16 1 Creation History of modifications...

Page 3: ...eon Mobile 11 PRESENTATION OF THE PALLEON MOBILE Presentation 13 PRESENTATION OF THE PALLEON CONTROL UNIT Intervention screen 15 Maintenance screen 16 Daily report screen 17 PROCEDURE OF INTERVENTION...

Page 4: ...point pressurized injection device compliant with the requirements of EN 16327 Palleon can be used with soft water or seawater Palleon is designed to be installed on fire trucks used under normal oper...

Page 5: ...5 PERFORMANCES...

Page 6: ...of the foam pump 30 L mn Dimensions of the motor pump unit 600 mm L x 400 mm l x 320 mm H Total weight 41 Kg Compatible foam concentrate Class B according to DIN EN 2 See compatible foam concentrate...

Page 7: ...F Freedol Fluoro Free used at 3 or 6 3FFF ARF Filmex 1 3 3FFF ARF Filmex 3 3 3FFF ARF Filmex 3 6 3FFF ARF Polarex 3 3FFF ARF Polarex 6 3FFF PF PRO397 3FFF PF PRO694 3FFF PF FP397 3FFF PF FP694 3FFF PF...

Page 8: ...LM 6 6 EAU FEU SFPM 3 3 EAU FEU SFPM 6 6 EAU FEU TRIDOL S3 EAU FEU TRIDOL S6 EAU FEU PETROFILM 3XT EAU FEU PETROFILM 6XT EAU FEU FLUOROPOLYDOL EAU FEU FP 570 EAU FEU FP 70 EAU FEU EXPANDOL EAU FEU SFP...

Page 9: ...A 4P UNISER UNISERAL A 104 AR UNISER UNISERAL A106 A4P UNISER UNISERAL AF 12 S 6 UNISER UNISERAL AF20A4P3 6 UNISER UNISEROL PFP 3 6 UNISER UNISEROL PFP 6 6 UNISER UNISERAL AF 20 US FOAM 1 3 Alcohol R...

Page 10: ...10 HYDRAULIC DRAWING...

Page 11: ...11 Palleon Mobile Hydraulic drawing...

Page 12: ...12 PRESENTATION OF THE PALLEON MOBILE...

Page 13: ...13 Presentation Pre mix output Palleon screen Adapters injection manifold Power cable Foam concentrate suction Water intake Suction pipe DN 25 Manometer Injection pressure...

Page 14: ...14 PRESENTATION OF PALLEON SCREEN...

Page 15: ...maintenance screen and priming in intervention T2 Button for reducing the concentration percentage mini 0 1 T3 Button for increasing the concentration percentage maxi 1 T4 Button for start and stop t...

Page 16: ...AND USING BUTTON T1 Button for accessing to the DAILY REPORTS T2 Button for accessing to the SECURE MENU T4 Button EXIT return to the home screen INFORMATION DISPLAY ON THE SCREEN 1 Serial number of...

Page 17: ...USING BUTTON T1 Button GUM to clear the daily reports T2 Button NEXT PAGE T3 Button PREVIOUS PAGE T4 Button EXIT return to the home screen INFORMATION DISPLAY ON THE SCREEN 1 Quantity of water used 2...

Page 18: ...18 INTERVENTION PROCEDURE...

Page 19: ...Press START Dosing begins automatically when the water flow rate is higher than 50 l mn PALLEON keep the concentration depending the water flow wi thout any action from the users Check the injection...

Page 20: ...e in a canister of water Press the button TOOL Press the button FLUSHING Start the flushing by pressing the button START When clear water flows out the priming outlet stop flushing by pressing the but...

Page 21: ...flow rate becomes higher than the measuring threshold EFFECTS CAUSES The water flow rate value is blinking Excessive output If the flow rate is higher than the maximum mea suring performance the syste...

Page 22: ...22 MAINTENANCE PROCEDURE...

Page 23: ...D OFFERS MAINTENANCE CONTRACTS Clean out the pump 0 5 liter of oil is necessary Control valves and joints of the pump Control the brush of the electrical motor Control hydraulic and electrical circuit...

Page 24: ...isionis 01090 GU REINS France Tel 33 0 4 74 06 47 00 Fax 33 0 4 74 06 47 09 Email incendie ctd pulverisation com www ctd pulverisation com SAS simplified joint stock company with a capital of 150 000...

Reviews: