background image

23

If a notification appears that there is no available upgrade, the driver will have to 

be installed manually . 
The first step is to go to the link below – 

https://ftdichip.com/drivers/vcp-drivers/

Scroll down to the download link section and select the setup executable option 

on the left side . 

Save the file – it will be saved as CDMXXXX_Setup . 

Retrieve the file from the Downloads section of your File Manager, and run the 

program . 

Summary of Contents for SC310 Series

Page 1: ...SC310 Series Signal Conditioner SC310 Series Signal Conditioner Product Manual Product Manual...

Page 2: ...ion 3 Installation 4 Signal Conditioner Configuration 6 Operation 16 Verifying Driver Support for Configuration 20 Troubleshooting 24 Software End User Agreement 28 Maintenance 38 Warranty and Return...

Page 3: ...emperature sensor input voltage SC310 Series Overview The SC310 signal conditioner is a DIN rail mountable component used in continuous machinery monitoring applications It provides signal conditionin...

Page 4: ...ctrical Connections 1 2 3 4 9 10 11 12 5 6 7 8 13 14 15 16 Temperature Output Temperature Output Dynamic Output Channel 1 Output Channel 1 Output CAN High CAN Low Dynamic Output Power In Power In Temp...

Page 5: ...rminals 11 and 12 for channel one s 4 20 mA signal proportional to the vibration level 4 Connect output device to terminals 1 and 2 to obtain the 4 20 mA signal representative of temperature level 5 T...

Page 6: ...n signal conductor wire which will then be run to a separate SC300 on terminal 13 The black common conductor will be run to one of the signal conditioners at terminal 14 then must be daisy chained to...

Page 7: ...pplication files log files and database records Installing the Configuration Software 1 Log into your account on the CTC website a On the resulting page scroll down to the information panel and click...

Page 8: ...may pop up asking about compressed folders Click Extract all 4 Double click the exe file located in the folder to launch the installer a Windows security might attempt to block the installer on launch...

Page 9: ...tion for the program files to be installed If a different location is preferred click Browse and set the new destination Click Next 8 By default the program will add a launch button to the Windows Sta...

Page 10: ...to include either a desktop icon or a Windows Start Menu launcher If neither of these options were included during installation it is still possible to launch the software by typing Signal Conditione...

Page 11: ...currently discouraged to plug multiple devices in at the same time due to a limitation of the USB serial drivers that cause the devices to lock up if any two USB COM ports read or write at the same ti...

Page 12: ...d configuration values The Part Number text box will also change the selected configuration values if a part number is typed or pasted into the box The Serial Number box will display the serial number...

Page 13: ...le to edit Full Scale Range corresponds to the dynamic range of the measurement and combined with Output Units make up the scaling for the output control signal The maximum selectable full scale range...

Page 14: ...it up the output units such as integrating for velocity on channel one and monitoring channel two for acceleration The Default Configuration button will load all dropdown menus with the standard ISO c...

Page 15: ...by clicking View Errors If errors are present on the device View Errors will read them and display information about the error s for corrective action Any errors that appear may be cleared from the d...

Page 16: ...e in the top menu will allow the user to select an option to view previous configurations Selecting this option will open the computer s default text file viewer with a log containing the date time se...

Page 17: ...es the need for any adjustments to the analog output Indicators The LED on the front of the signal conditioner will indicate the status of the signal conditioner State 1 Normal Operation LED is solid...

Page 18: ...ve been caused due to physical damage or misuse Processing will be disabled in this case Communication with the configurator may or may not work depending on the root cause but should be attempted as...

Page 19: ...voltage from the temperature sensor to an exact 4 20 mA value This functionality is only applicable with a CTC TA200 Series dual output sensor Output mA Temperature C Signal Conditioner 4 20mA Tempera...

Page 20: ...turned off Although the BNC connector circuitry offers short circuit protection and can safely sink the current long term degradation may occur due to increased power dissipation depending on the magn...

Page 21: ...k the USB connection to make sure it is secure Confirm that the LED indicator on the SC300 unit is lit up with a solid orange light LED will blink when first plugged in and should then turn solid oran...

Page 22: ...uld search for and install the necessary driver If the driver updates correctly there will no longer be a USB Serial Port option in the Other Devices section and a new option will appear in the Ports...

Page 23: ...he first step is to go to the link below https ftdichip com drivers vcp drivers Scroll down to the download link section and select the setup executable option on the left side Save the file it will b...

Page 24: ...Manager If all is correct USB Serial Port COMX will be displayed in the Ports section of the drop down menu When this appears open the CTC Signal Conditioner program The SC300 will appear with a seria...

Page 25: ...fying Driver Support for Configuration page The device may take as long 40 seconds for the software to recognize the signal conditioner This will be especially true with signal conditioners older than...

Page 26: ...med 4 20 mA or 0 5 10 Vdc output is lower than expected Check filter settings Make sure low pass and high pass filters have been set to range capable of capturing the expected frequencies Ensure the r...

Page 27: ...um for voltage configurations For current configurations load must be configured so that compliance voltage voltage powering the device is not exceeded 1k maximum recommended for a compliance voltage...

Page 28: ...configuring CH1 Error configuring CH2 Error configuring CH1 CRC Error configuring CH2 CRC Once installed and connected to an online system PLC DCS SCADA the values that the system receives do not mat...

Page 29: ...L NUMBER FROM THE SIGNAL CONDITIONER IN THE BOX AND CLICKING ACCEPT YOU A ACCEPT THIS AGREEMENT AND AGREE THAT LICENSEE IS LEGALLY BOUND BY ITS TERMS AND B REPRESENT AND WARRANT THAT YOU HAVE THE RIGH...

Page 30: ...in this Agreement CTC hereby grants to Licensee a non exclusive non transferable non sublicensable limited license in the Territory during the Term to solely by and through its Authorized Users a down...

Page 31: ...n any other programs e reverse engineer disassemble decompile decode or otherwise attempt to derive or gain access to the source code of the Software or any part thereof f remove delete alter or obscu...

Page 32: ...this Agreement s provisions as applicable to such Authorized User s use of the Software and shall cause Authorized Users to comply with such provisions 6 Compliance Measures Licensee authorizes CTC t...

Page 33: ...ffect until terminated as set forth herein the Term Licensee may terminate this Agreement by ceasing to use and destroying all copies of the Software and Documentation CTC may terminate this Agreement...

Page 34: ...LICENSEE AS IS AND WITH ALL FAULTS AND DEFECTS WITHOUT WARRANTY OF ANY KIND TO THE MAXIMUM EXTENT PERMITTED UNDER APPLICABLE LAW CTC ON ITS OWN BEHALF AND ON BEHALF OF ITS AFFILIATES AND ITS AND THEIR...

Page 35: ...Licensee except for information which is i already known by the Licensee ii becomes through no act or fault of the Licensee publicly known iii received by Licensee from a third party without a restri...

Page 36: ...f its obligations under Section 9 or in the case of Licensee Sections 2 4 7 b 11 or 12 would cause the other Party irreparable harm for which monetary damages would not be an adequate remedy and agree...

Page 37: ...effect and be binding upon the parties hereto f Section Headings The headings of the sections paragraphs and appendices herein are for the Parties convenient reference only and shall not define or lim...

Page 38: ...written and comparable terms refer to printing typing and other means of reproducing words including electronic media in a visible form References to any agreement or contract are to that agreement or...

Page 39: ...ver fail we will repair or replace it at no charge Refund All stock products can be returned for a 25 restocking fee if returned in new condition within 90 days of shipment Stock products qualify for...

Reviews: