CHAPTER 3
INTRODUCTION TO CLI
Negation:
(config)# no lldp med datum
3.9.26.6 (config)# lldp med fast
Syntax:
(config)# lldp med fast <v_1_to_10>
Explanation:
Rapid startup and Emergency Call Service Location Identification Discovery of endpoints is a critically
important aspect of VoIP systems in general. In addition, it is best to advertise only those pieces of information which
are specifically relevant to particular endpoint types (for example only advertise the voice network policy to permitted
voice-capable devices), both in order to conserve the limited LLDPU space and to reduce security and system integrity
issues that can come with inappropriate knowledge of the network policy. With this in mind, LLDP-MED defines an
LLDP-MED Fast Start interaction between the protocol and the application layers on top of the protocol, in order to
achieve these related properties. With Fast start repeat count it is possible to specify the number of times the fast
start transmission is repeated. The recommended value is 4 times, giving that 4 LLDP frames with a 1 second interval
will be transmitted, when a LLDP frame with new information is received. It should be noted that LLDP-MED and the
LLDP-MED Fast Start mechanism is only intended to run on links between LLDP-MED Network Connectivity Devices
and Endpoint Devices, and as such does not apply to links between LAN infrastructure elements, including between
Network Connectivity Devices, or to other types of links.
Parameters:
<v_1_to_10>: Specify a valid value between 1 and 10.
Example:
Set the value to 5.
Example:
Set the holdtime to 5.
Negation:
(config)# no lldp med fast
3.9.26.7 (config)# lldp med location-tlv altitude
Syntax:
(config)# lldp med location-tlv altitude { meters | floors } <v_word11>
Explanation:
Altitude SHOULD be normalized to within -32767 to 32767 with a maximum of 4 digits. It is possible to
select between two altitude types (floors or meters). “meters” means meters of Altitude defined by the vertical datum
specified; while, “floors” means altitude in a form more relevant in buildings which have different floor-to-floor
dimensions.
Parameters:
{ meters | floors }: Specify one of the options.
<v_word11>: Specify a value for the specified option.
Example:
Set the altitude value to “floors 10”.
Example:
Set the holdtime to 5.
# config t
(config)# lldp med fast 5
# config t
(config)# lldp med datum wgs84