CTC Union MAX X Box Product Manual Download Page 13

13

Warranty & Refund

Warranty 

All CTC products are backed by our unconditional lifetime warranty . If any CTC 

product should ever fail, we will repair or replace it at no charge .

Refund 

All stock products qualify for a full refund if returned in new condition within 90 

days of shipment . Build to order products qualify for a 50% refund if returned in 

new condition within 90 days of shipment . Custom products are quoted and built 

specifically to the requirements of the customer, which may include completely 

custom product designs or private labeled versions of standard products for 

OEM customers . Custom products ordered are non-cancellable, non-returnable 

and non-refundable . 

Mm-Mmx1000-12/Rev A

Summary of Contents for MAX X Box

Page 1: ...MMX1000 Series Modular MAXX Box MMX1000 Series Modular MAXX Box 3 12 Channel 3 12 Channel Product Manual Product Manual...

Page 2: ...uct Description 3 Product Dimensions Diagram 4 Mounting Instructions 5 Conduit Entry 6 Grounding 7 Installation of Sensor Signal Input Cable 8 Post Installation Testing 11 Warranty Return Information...

Page 3: ...onnect terminal blocks for terminating the sensor of your choice Note If continuous output is desired CTC part number JB907 4A will accomplish that application Setup of DIP Switches In addition to the...

Page 4: ...4 Product Dimensions Measurement Location Card BNC Output Connector Figure 1 Dimensions Figure 2 Diagram Side View Rear View...

Page 5: ...without cable entries provided you should add your own entry prior to mounting the modular MAXX box CTC does not recommend putting holes in the top of the enclosure due to access and moisture concern...

Page 6: ...enters from the bottom of the enclosure when mounted Note To ensure moisture will not flow into the enclosure a hole should be drilled at the lowest point in the conduit to provide drainage for any m...

Page 7: ...grounded to earth ground A Mounting to Earth Ground When mounting MMX1000 Series Modular MAXX boxes to earth ground such as an I Beam mount the shield ground wire using a mounting bolt through one of...

Page 8: ...d Figure 6 Ground Wire Placement Sensor Installation Installation of sensors signal input cable 1 Feed blunt end through the cable entry at the bottom of the enclosure Note it is recommended that cabl...

Page 9: ...in wire Signal Power 4 Locate the appropriate plug identified by channel number remove the plug and install the wires using a small flathead screwdriver Push plug back into location Orientation is as...

Page 10: ...ed on the inside front cover with a description of each measurement location Figure 10 Connecting Cables to Termination box GND GND GND GND GND GND GND GND GND Sensor Inputs Red Positive Vibration Bla...

Page 11: ...ermination box while Person B will be located at the measurement location 2 Once positioned Person A will connect the TM1018 to the data collector output to the modular MAXX box and turn the Channel S...

Page 12: ...2 Yellow LED Open Circuit Indicates one of the following a Cable connector is not connected to accelerometer b Cable is open circuit broken or not connected one end c Accelerometer is not functioning...

Page 13: ...condition within 90 days of shipment Build to order products qualify for a 50 refund if returned in new condition within 90 days of shipment Custom products are quoted and built specifically to the re...

Reviews: