Mechanical
Housing: IP54 grade rugged metal housing protection
Fanless design
Dimensions: 113 mm (D) x 260 mm (W) x 132 mm (H)
Installation Method: Wall-mounting
Weight: 2.8kg
Environmental
Operating Temperature: -40°C
~
75°C
Storage Temperature: -40°C
~
85°C
Humidity: 5%
~
95% (Non-condensing)
Certifications
EMC: CE (EN55024, EN55032)
EMI (Electromagnetic Interference): FCC Part 15 Subpart B Class A, CE
Railway Traffic: EN50155, EN50121-4
Fire Protection of Railway Vehicle: EN45545-2
Immunity for Heavy Industrial Environment: EN61000-6-2
Emission for Heavy Industrial Environment: EN61000-6-4
EMS (Electromagnetic Susceptibility) Protection Level:
EN61000-4-2 (ESD) Level 3, Criteria B
EN61000-4-3 (RS) Level 3, Criteria A
EN61000-4-4 (Burst) Level 3, Criteria A
EN61000-4-5 (Surge) Level 3, Criteria B
EN61000-4-6 (CS) Level 3, Criteria A
EN61000-4-8 (PFMF, Magnetic Field) Field Strength: 300A/m,
Criteria A
Safety: EN60950-1
4KV Surge Protection: PoE and UTP ports
Shock: IEC 61373
Freefall: IEC 60068-2-32
Vibration: IEC 61373
MTBF (MIL-HDBK-217)
238,600 Hours