background image

10

 - 

w  w  w  .  C  T  C  U  .  c  o  m 

<2> 

ALS:

 Enable or disable ALS function. Automatic Laser Shutdown (ALS) 

is  a  technique  used  to  automatically  shut  down  the  output  power  of  the 
transmitter in case of fiber break according to ITU-T G.664. This is a safety 
feature  that  prevents  dangerous  levels  of  laser  light  from  leaking  out  of  a 
broken fiber, provided ALS is provisioned on both ends of the fiber pair. The 
sequence  of  events  is  as  follows.  If  a  fiber  is  cut, the  receiver  will detect a 
Loss  Of  Signal  (LOS).  The  ALS  agent  will  turn  off  the  transmitter.  The 
receiver at the far end will then detect an LOS and its ALS agent will turn off 
the transmitter. In this way the entire fiber will go dark. 
 
<D>

DD Information:

 View digital diagnostics information of the inserted 

SFP transceiver.   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Device Information And Configuration

 

 

 
 
 
 
 
 
 
 

   << Device Information And Configuration >> 
 
            Alarm: [LOS] 
 
            <1> Device Active  [Enable ] 
            <2> Device Reset 
            <3> Device Default 
            <4> Input Debounce [Disable] 
 
            [ESC] Go to previous menu. 
 
         

                ***************************************** 
                ***  CTC UNION TECHNOLOGIES CO.,LTD.  *** 
                ***      FRM220-CCF40    Manager      *** 
                ***************************************** 
                Ver:[1.000-1.000-0.010-0.000] [CH-01M   ] 
 
            << SFP+ Digital Diagnostics >> 
 
 
            Vendor Name    [CTC UNION       ] 
            Vendor Number  [SFS-7010-L31(I) ] 
            Fiber Type     [Single Mode     ] 
            Tx Wave Length [1310 nm         ] 
            Rx Wave Length [1310 nm         ] 
            Link Length    [0010 Km         ] 
 
 
            [ESC] Go to previous menu. 

Summary of Contents for FRM220-CCF20

Page 1: ......

Page 2: ...zi St Neihu Taipei 114 Taiwan T 886 2 26591021 F 886 2 26590237 E sales ctcu com techsupport ctcu com marketing ctcu com H www ctcu com 2017 CTC Union Technologies Co LTD All trademarks are the property of their respective owners Technical information in this document is subject to change without notice ...

Page 3: ...ents Version 1 0 August 2017 Introduction 1 Features Specifications 2 Panel 3 Installation SFP 4 LED Indicators 5 Console Management 6 Main Menu Operation 7 Channel Information and Configuration 8 Fiber Information and Configuration 9 Device Information and Configuration 10 Upgrading 11 Application 14 ...

Page 4: ...ental control systems fire alarm systems gate control traffic signal control equipment and more WARNING Fiber optic equipment may emit laser or infrared light that can injure your eyes Never look into an optical fiber or connector port Always assume that fiber optic cables are connected to a laser light source Management Features FRM220 CCF40 has an embedded processor which can be used to configur...

Page 5: ...rate 155Mbps Duplex mode Full duplex Distance 2KM Multimode 30KM Single mode 50KM Single mode Wavelength 850nm 1310nm 1550nm Relay Contact Input Contact I1 I2 I3 I4 Input Dry Contact Closure 4 inputs I1 I2 I3 I4 Removable terminal block connector Output Contact K1 K2 K3 K4 Output SPST relay 4 outputs K1 K2 K3 K4 Normally open Removable terminal block connector Relay Contact Power Output Rating Res...

Page 6: ...vironment Operating Temperature 0 C 50 C Storage Temperature 10 C 85 C Humidity 5 95 non condensing MTBF 100 000 Hours Panel No Description 1 Thumb screw 2 SFP slot 3 Power System Link Test Alarm LED indicators 4 Removable terminal block for input contacts COM and output contacts 5 Input contacts I1 I2 I3 I4 COM output contacts K1 K2 K3 K4 LED indicators Panel Index Reference 5 4 3 2 1 ...

Page 7: ...dirt dust and mishandling especially in high speed networks Dirty or mistreated fiber may cause errors and an unwanted degradation of signal quality Remove the dust caps on SFP and patch cables only when ready to plug in optical cables Installation CTC Union supplied SFP modules are of the Bale Clasp type The bale clasp pluggable module has a bale clasp that secures the module into the SFP cage In...

Page 8: ...ions PWR Green On Power on Off No power Flash 1 Upgrade firmware On Off 100ms 2 Device is in disable mode On 1 second Off 4 seconds System Green On Normal Off System errors Link Green On Link up and sync Flash Link up but sync loss On Off 100ms Off Loss of signal Alarm Test Red On Link down sync loss or power error Off Normal Flash Local loopback test or loopback detected On Off 100ms CH1 4 Input ...

Page 9: ...its none Stop bits 1 Handshaking none Emulation VT 100 Default username password admin admin Connect the serial cable to the chassis DB9 Run the terminal emulation program About 3 seconds after being powered on the FRM220 CCF40 will display the login menu as shown in the following example Example of Login Menu Console Screen NOTE All settings done by console menu are ignored if the card is placed ...

Page 10: ...ctive enable or disable Loopback and ALS function in this menu 3 Device Information And Configuration Enter this menu to enable disable the device reset the device set the device to factory default settings and enable disable Input Debounce function U Update with X Modem Update firmware via X Modem S Store Parameters Saves the setting parameters into non volatile RAM NVR P Password Setup Enter thi...

Page 11: ...er whether there is actual input or not Force Off is to turn off the channel 02 3 Channel 03 Select 3 to set up how relay of Channel 03 is controlled Three methods are provided One is By Input which means the relay is triggered by actual input signals Force On is to put the Channel 03 in shorted state no matter whether there is actual input or not Force Off is to turn off the channel 03 4 Channel ...

Page 12: ...rter incorporates loop back features which allow loop back testing to confirm that the fiber optic connection is operating normally or not Fiber Port Information And Configuration Exist Fault Link Sync SFP Status No 1 Port Active Enable 2 Loopback Disable 3 ALS Disable D DD Information ESC Go to previous menu LLB Local Loop Back Remote Side Fiber SFP Local Side Fiber SFP TX RX RX TX Remote Side Fi...

Page 13: ...n off the transmitter The receiver at the far end will then detect an LOS and its ALS agent will turn off the transmitter In this way the entire fiber will go dark D DD Information View digital diagnostics information of the inserted SFP transceiver Device Information And Configuration Device Information And Configuration Alarm LOS 1 Device Active Enable 2 Device Reset 3 Device Default 4 Input Deb...

Page 14: ...evice can stabilize bouncing situations when power signals are rising and falling constantly Upgrading Stand alone Firmware Upgrading via Xmodem The FRM220 CCF40 card may be firmware upgraded using XMODEM when placed in the chassis such as CH02M The user may use serial terminal such as a notebook computer that has an RS232 port or via a commonly available USB to RS232 adapter Then use a serial ter...

Page 15: ...c o m 2 Select Y and then send Firmware file via Xmodem and select the Firmware file that you want to upload 3 Start upgrading new Firmware image 4 Check the Firmware version after completing the Firmware upgrade process ...

Page 16: ...tem Configuration Setup Then U Upgrade Line Card Menu Select the line card type FRM220 CCF40 and local unit Enter filename The upgrade should complete in only a couple of minutes DO NOT disconnect or pullout insert any other cards during the upgrade process CTC UNION TECHNOLOGIES CO LTD FRM220 NMC VER 3 45 Upgrade Line Card Menu Target IP 59 125 162 252 Target Gateway 59 125 162 241 TFTP Server IP...

Page 17: ...put and then sends signals via fiber optic to the remote device The remote device reacts depending on signals received See below for the illustrative application diagram Multimode fiber up to 2KM Single mode fiber up to 50KM FRM220 CCF40 FRM220 CCF40 Output I1 COM shorted Fiber K1 K2 COM K3 K4 I2 I1 I3 I4 Input K1 K2 COM K3 K4 I2 I1 I3 I4 Fiber ...